Related Experiment Video
Updated: Feb 7, 2026

Meta-Analysis of the Effectiveness and Safety of Shugan Jieyu Capsules for the Treatment of Insomnia
Published on: February 17, 2023
Instrument-based, non-cycloplegic versus cycloplegic refraction in pediatric and young adult populations (≤25 years):
Ana Roque1, Amélia Fernandes Nunes2, Henrique Nascimento1
1Lisbon Higher Institute of Education and Sciences (ISEC Lisboa), Lisbon, Portugal.
Background:
Accurate refractive assessment in children and young adults is critical to prevent amblyopia and strabismus, conditions that may arise from uncorrected hyperopia. Although non-cycloplegic autorefractors and photoscreeners are increasingly used for vision screening due to their practicality and high testability, residual accommodation often introduces systematic measurement bias. The debate regarding the necessity of cycloplegia has intensified, particularly in large-scale epidemiological studies and screening programs, highlighting the need for an evidence-based synthesis.
Methods:
This systematic review and meta-analysis, conducted according to PRISMA and AMSTAR-2 standards and registered in PROSPERO (CRD420251134665), synthesized data from 54 comparative studies, with 24 included in quantitative analyses.
Results:
Compared with cycloplegic reference methods, non-cycloplegic autorefractors and photoscreeners consistently underestimated refractive error, showing pooled mean differences of -0.65 D (95% CI: -0.84 to -0.45; 95% PI: -1.50 to +0.20 D) and -0.78 D (95% CI: -1.12 to -0.44; 95% PI: -1.70 to +0.10 D), respectively. These prediction intervals illustrate the wide variability expected across future studies and populations. The bias was most pronounced in younger children and hyperopic eyes, reflecting the impact of accommodative tone. Despite device-specific differences, no method fully corrected this systematic error. Testability exceeded 95% across most devices, reinforcing their feasibility for population-level screening. However, the certainty of evidence was rated as low due to heterogeneity and observational design limitations.
Conclusions:
Non-cycloplegic methods systematically underestimate hyperopia and therefore cannot replace cycloplegia for definitive diagnosis or spectacle prescription in pediatric populations. Cycloplegic assessment remains essential to detect amblyogenic refractive errors accurately. Non-cycloplegic methods may be integrated into large-scale screening programs for initial case detection, but positive or borderline cases must undergo cycloplegic confirmation to ensure safe and effective clinical management.
More Related Videos
06:26Meta-analysis of Voxel-Based Neuroimaging Studies using Seed-based d Mapping with Permutation of Subject Images SDM-PSI
Published on: November 27, 2019
08:36Author Spotlight: Evaluating the Adjuvant Efficacy and Safety of Angong Niuhuang Pill in Viral Encephalitis Treatment
Published on: April 19, 2024
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Analysis of Population Pharmacokinetic Data
Conservation of Small Populations
Uncertainty in Measurement: Reading Instruments
What is Population Genetics?