Related Experiment Video
Updated: Feb 7, 2026

Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography
Published on: February 9, 2019
Deep-learning-based optical coherence tomography reconstruction for high-speed and contrast morphology and
Yudan Chen1, Shuo Chen2, Jun Song1
1University of British Columbia, School of Biomedical Engineering, Faculty of Medicine and Applied Science, Vancouver, British Columbia, Canada.
Significance:
Spectral-domain optical coherence tomography (SD-OCT) has been widely used in clinical ophthalmic imaging for high spatial resolution and phase stability. The implementation of multiple spectrometers could help resolve the challenges of SD-OCT, including limited imaging speed and sensitivity. However, these two improvements cannot be achieved concurrently.
Aim:
We propose a deep-learning-based approach to enhance both imaging speed and sensitivity of SD-OCT systems using a modified U-Net architecture.
Approach:
This network adopts a visual state space model to synthesize the high signal-to-noise ratio (SNR) OCT and OCTA from high-speed acquisitions, which bypasses the hardware restriction. The model performance is evaluated both qualitatively and quantitatively using the multiscale structural similarity index measure (MS-SSIM) and contrast-to-noise ratio (CNR).
Results:
The results demonstrate effective performance in high-SNR OCT/OCTA reconstruction, providing better contrast between the retinal layers and improved delineation of layer boundaries. Fine structures in both the inner and outer retina, such as microcapillaries and choroid, are successfully restored.
Conclusions:
We proposed an effective approach to improve the OCT image quality while maintaining the high acquisition speed using the DNN-based architecture, enabling simultaneous benefits of high imaging speed and enhanced sensitivity.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Speed of Sound in Gases

