Evaluation of computer-aided detection for gastric cancer using white-light and linked-color imaging: a pilot study
Takeshi Yasuda1, Narutoshi Ando1, Tamae Hashimoto1
1Department Gastroenterology, Akashi City Hospital, Hyogo, Japan.
Background And Aims:
In recent years, the field of endoscopic artificial intelligence has seen significant advancements, largely because of the widespread implementation of deep learning techniques. However, the computer-aided detection (CADe) of the stomach poses significant challenges in clinical practice. Here, we evaluated the performance of a newly developed CADe system, CAD EYE (Fujifilm, Tokyo, Japan), by comparing the frequency of the detection box appearance with white-light imaging (WLI) versus linked-color imaging (LCI) during the process of detecting gastric cancer (GC) and detection of GC with and without CADe.
Methods:
This single-center observational retrospective study included 105 patients who underwent esophagogastroduodenoscopy (EGD) using CADe and 105 controls selected by propensity-score matching from 600 patients. The primary outcome was to compare the detection box appearance of WLI and LCI during the CADe observation. Secondary outcomes included comparisons of biopsy rates, examination times, and cancer detection rates between groups. Furthermore, we investigated whether the landmark checker could accurately identify the stomach site.
Results:
CADe exhibited an average of 6.2 false-positive detections per case. False-positive rates were significantly lower with LCI than with WLI (3.48 vs 7.70, P < .001). The GC detection rate was higher in the CADe group than in the control group (4.8% vs 1.8%, P = .07), although the difference was not statistically significant. Biopsy rates and examination times were comparable between the groups. CADe accurately detected all 18 known-early GC cases. The landmark checker function identified an average of 5.72 of 7 key gastric sites (81.7%).
Conclusions:
This pilot study suggests that CADe, particularly when combined with LCI, may enhance GC detection during EGD without significantly increasing the examination time. Although promising, a high false-positive rate indicates that further optimization is needed.
Related Concept Videos
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Pilot and Numeric Relaying
Color Vision
Covalently Linked Protein Regulators
These groups modify specific amino acids in a protein....
Gastric Emptying
Gastric Motility
Peristaltic Waves and Chyme Formation
Upon food entry, the stomach initiates...