Clinical validation of a novel accelerometer-based respiratory rate monitor
O M Steihaug1, T E Sjøset2,3, A S Stordal4
1Department of Internal Medicine, Haraldsplass Deaconal Hospital, Bergen, Norway.
Abstract:
Respiratory rate (RR) is a vital sign often unused in clinical practice due to labour-intensive manual counting or capnography limitations in spontaneously breathing patients. This study validated RespX, a novel accelerometer-based wireless sensor, for continuous respiratory rate measurement in hospitalised patients. This prospective, single-centre observational study included hospitalised adults (> 18 years) expected to remain undisturbed for one hour while measuring RR. The RespX sensor, placed on the left chest wall, was compared with continuous capnography and manual counting every 20 min for one hour. The primary endpoint was respiratory rate measured by RespX within ± 3 breaths per minute compared to capnography. Linear mixed-effects models analyzed mean differences between methods. Twenty-nine patients completed the study. The proportion of RespX measurements within ± 3 breaths per minute of capnography was 77% (95% CI: 74.8-79.0%) for raw data and 82.8% (95% CI: 80.7-84.7%) after removing outliers. The proportion of RespX measurements within ± 3 breaths per minute of manual counting was 87,5% (95% CI: 81,1%-93,8%). For the capnography the proportions for the raw data was 87,8% (95% CI: 81,8-93,8%) and 94,5% (95% CI: 90,3%-98,7%) after removing outliers. Linear mixed-effects analysis showed mean differences of -0.40 (p = 0.43) for raw data and 0.39 (p = 0.15) for filtered data between RespX and capnography, supporting their equivalence. RespX demonstrated lower measurement variability (SD: 0.75-3.05) compared to capnography (SD: 0.99-5.19). No adverse events were observed during the study. The wireless RespX accelerometer-based sensor provides a novel and accurate method for assessing the respiratory rate in awake hospitalised patients compared with capnography.Trial registration: NCT06911541.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Reliability and Validity
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Respiratory Regulation of Acid-Base Balance
When carbon dioxide levels increase in the blood, more H+ and HCO3⁻ are...
Measuring Reaction Rates
Anatomy of Respiratory System II: Lower Respiratory Tract
The Larynx
It is located between the pharynx and the trachea, acts as a passageway for air, and hosts several critical structures, such as the epiglottis, vocal cords, and glottis. The epiglottis acts as a gateway, guiding food to the...