Related Experiment Video
Updated: Feb 8, 2026

Studying Triple Negative Breast Cancer Using Orthotopic Breast Cancer Model
Published on: March 20, 2020
A comparison of the static stiffness index between a compression garment and an adjustable device in breast
Leila Pereira1, Jéssica Malena Pedro da Silva1, Suzana Sales de Aguiar1
1Division of Clinical Research and Technological Development, Brazilian National Cancer Institute (INCA), Rio de Janeiro, RJ, Brazil.
Objective:
To compare the static stiffness index (SSI) between a compression garment and a ReadyWrap (Venosan, Brazil) adjustable compression garment (ACG), and analyse the clinical factors associated with increased SSI in patients with breast cancer-related lymphoedema (BCRL).
Method:
In this cross-sectional study, working pressure (WP) and resting pressure (RP) were assessed using a PicoPress device (Venosan, Brazil) positioned under the biceps muscle in the arm region. The SSI was calculated as the absolute and relative difference between the RP and the highest WP recorded during muscle contraction.
Results:
The study included 76 patients with a mean age of 61.7±12.6 years. During compression garment use, the mean RP was 21.9mmHg and mean WP was 40.0mmHg during biceps brachii contraction, resulting in an absolute SSI of 18.1mmHg and a relative SSI of 43.6% (p<0.001). For the ACG, the mean RP was 19.3mmHg and mean WP was 63.1mmHg, resulting in a mean SSI of 43.8mmHg and a relative SSI of 68.7% (p<0.001). The ACG produced an SSI 25.7mmHg greater than the compression garment, a 25.1% relative difference (p<0.001). The compression garment showed a higher SSI in early-stage versus advanced-stage patients (8.2%; p=0.003) and in those with conservative surgeries versus mastectomy (8.3%; p=0.005). No SSI difference was observed for the ACG when considering tumour characteristics and oncological treatment.
Conclusion:
The SSI was greater with ACG use compared with the compression garment. Patients who had breast-conserving surgeries and early-stage tumours showed the highest SSI when using the compression garment. No SSI differences were found regarding patient demographic, clinical, tumour or treatment characteristics during ACG use.
More Related Videos
Related Concept Videos
Cross-Sectional Research
Finding Volume Using Cross-Sectional Area
Profile Leveling and Cross Sections
Spinal Cord: Cross-sectional Anatomy
Gray Matter and its Components
Central to the gray matter is...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Crossing Over
The homologous pairs of sister chromosomes—one from the maternal and one from the paternal genome—then begin to align alongside each other lengthwise, matching corresponding DNA positions in a process...