Use of Brain MRI in Cerebral Adrenoleukodystrophy: International Recommendations for Screening, Monitoring, and

Hemmo A F Yska1, Marianne Golse2, Damien Galanaud2

  • 1INSERM U 1127, CNRS UMR 7225, Sorbonne Université, UPMC Univ Paris 06 UMR S 1127, Institut du Cerveau, ICM, France.

Neurology
|February 6, 2026
PubMed
Abstract

Insights

This study establishes consensus on MRI protocols for cerebral adrenoleukodystrophy (CALD) screening and monitoring. Key sequences are identified to improve early detection and guide future research in adrenoleukodystrophy (ALD).

Area of Science:

  • Neurology
  • Radiology
  • Medical Imaging

Background:

  • Cerebral adrenoleukodystrophy (CALD) is a common manifestation of adrenoleukodystrophy (ALD) in men, requiring early MRI detection for timely intervention.
  • Current MRI protocols for CALD screening and follow-up lack international consensus, hindering standardized clinical practice.

Purpose of the Study:

  • To establish expert consensus on optimal MRI sequences for CALD screening and lesion monitoring in clinical practice.
  • To identify priority MRI sequences for future research applications in ALD.
  • To promote intercenter harmonization of MRI protocols for adrenoleukodystrophy.

Main Methods:

  • A modified Delphi procedure involving 30 international experts in ALD brain imaging was employed.
  • Experts used questionnaires and online consensus meetings to agree on MRI sequences for screening, monitoring, and research.
  • Agreement was reached on core sequences, specific clinical indications, and research priorities.

Main Results:

  • A core screening MRI protocol for ALD (adults and children) was defined, including 3D T1-weighted, T2-weighted, 3D FLAIR, and DWI sequences.
  • Postcontrast T1-weighted imaging is recommended for specific clinical scenarios, and DWI is supported for lesion progression assessment.
  • A research protocol prioritizing DTI, MR perfusion, and quantitative volumetric analyses was established.

Conclusions:

  • This international consensus harmonizes ALD MRI protocols, providing a practical framework for improved clinical decision-making.
  • The study identifies key MRI sequences for future research, focusing on areas lacking prior consensus.
  • Standardized MRI protocols are crucial for effective screening, monitoring, and advancing research in ALD.

Related Concept Videos

Internal Energy02:00

Internal Energy

The total of all possible kinds of energy present in a substance is called the internal energy (U), sometimes symbolized as E. Suppose a system with initial internal energy, Uinitial, undergoes a change in energy (transfer of work or heat), and the final internal energy of the system is Ufinal. Change in internal energy equals the difference between Ufinal and Uinitial.
36.8K
Internal Energy01:29

Internal Energy

The internal energy of a thermodynamic system is the sum of the kinetic and potential energies of all the molecules or entities in the system. The kinetic energy of an individual molecule includes contributions due to its rotation and vibration, as well as its translational energy. The potential energy is associated only with the interactions between one molecule and the other molecules of the system. Neither the system's location nor its motion is of any consequence as far as the internal...
7.1K
Internal Receptors01:31

Internal Receptors

Many cellular signals are hydrophilic and therefore cannot pass through the plasma membrane. However, small or hydrophobic signaling molecules can cross the hydrophobic core of the plasma membrane and bind to internal, or intracellular, receptors that reside within the cell. Many mammalian steroid hormones use this mechanism of cell signaling, as does nitric oxide (NO) gas.
74.7K
International System of Units01:29

International System of Units

The International System of Units, known as the SI system, is a universally accepted measurement system recognized and used worldwide. The SI system is based on a set of three base units considered absolute, and their values do not change with location. These base units are meters, kilograms, and seconds.
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...
5.1K
Internal and External Forces01:12

Internal and External Forces

Newton's first law states that a net external force causes a change in motion. External forces act on an object or system, originating outside of the object or system. In contrast, internal forces originate inside the system of interest and do not lead to any acceleration. In simpler words, internal forces are forces that act on one part of an object and are exerted by another part of the same object. External forces are forces that act on an object due to some other object. Therefore, when...
16.3K
International Nursing Organizations I01:23

International Nursing Organizations I

International Nursing Organization (ICN) is a global union of national nurses' organizations. Individual nurses can be a part of ICN through member organizations. Each member organization strives to ensure quality nursing care, sound health policies, the advancement of nursing knowledge, respect for the profession, and a satisfied and competent nursing workforce.
ICN member organizations work to advance the field of nursing and healthcare via policies, partnerships, lobbying, professional...
2.3K