Related Experiment Video
Updated: Feb 8, 2026

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Correlation between Electrical Synchrony Index values measured by Synchromax® and left ventricular mechanical
Hugo Villarroel-Ábrego1, Raúl Norberto Garillo2, Daniela Benzano Bumaguin3
1School of Medicine, Universidade Salvadoreña Alberto Masferrer, Hospital de Diagnóstico Escalón, 19 Av. Nte., San Salvador, El Salvador.
Background:
Left ventricular (LV) mechanical dyssynchrony results from nonuniform myocardial activation, leading to inefficient LV contraction and worse clinical outcomes. Synchromax® is a noninvasive system that performs real-time spatial variance analysis of QRS complexes from a standard electrocardiogram, generating an electrical synchrony index (ESI) that may be a potential marker of LV mechanical dyssynchrony. This study evaluated the efficacy of the ESI in predicting LV mechanical dyssynchrony compared to the gold standard: LV mechanical dispersion (LVMD) > 60 ms as measured by speckle-tracking strain echocardiography.
Methods:
A cross-sectional study was conducted with consecutive adult patients undergoing echocardiography in San Salvador, El Salvador. Clinical, electrocardiographic (rhythm, QRS duration, ESI), and echocardiographic (LVMD, LV ejection fraction, global longitudinal strain) data were collected.
Results:
Eighty-four studies from 83 patients were analyzed. Mean ESI was 0.36 ± 0.31 and mean LVMD was 58.4 ± 27.1 ms. The ESI showed a sensitivity of 70.0% and a specificity of 88.9%, with negative and positive predictive values of 84.2% and 77.8%, respectively. Agreement with the gold standard was moderate (kappa = 0.60; p < 0.001). ROC curve analysis demonstrated good discriminative performance (area under the curve = 0.81), superior to QRS duration (area under the curve = 0.71) for identifying LV mechanical dyssynchrony.
Conclusions:
The optimal ESI cutoff was 0.42. ESI correlated consistently and significantly with LVMD, indicating that it may be a more sensitive functional marker than QRS duration, especially in cases without evident dyssynchrony. The ESI is a simple, accessible tool for complementary assessment of ventricular electromechanical synchrony.
More Related Videos
06:34Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Measurements of Strain
Correlations
Biodiversity and Human Values
Professional Values
The values that are the foundation of the nursing profession are altruism, autonomy, human dignity, and social justice.
First, altruism refers to the concern for the welfare and well-being of others without personal...
Critical Values
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...