Switch-type photoelectrochemical aptasensor for microplastics and nanoplastics detection based on two-dimensional
Xiaoping Bai1, Gaosen Zhang2, Cong Tang1
1Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou, 730000, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China.
Abstract:
Microplastics and nanoplastics (MNPs) as emerging pollutants present substantial risks to both the environment and human health. Developing highly sensitive methods to rapidly identify and detect low concentrations of MNPs in complex systems remains a considerable challenge. Here, an "off-on" switch-type photoelectrochemical (PEC) aptasensor was employed for the sensitive detection of polyvinyl chloride (PVC) and polystyrene (PS) MNPs. This PEC aptasensor was based on a two-dimensional organic-inorganic Z-scheme heterojunction and utilized an acetylferrocene-modified aptamer (Apt-AcFc) as PEC recognition and quencher probes. In general, combining Apt-AcFc with the photoelectrode efficiently quenches the photocurrent, transitioning it to the 'off' state. Conversely, the presence of MNPs greatly increases the photocurrent because the MNPs were specifically recognized by Apt-AcFc, causing Apt-AcFc detaching from the photoelectrode and transition to the 'on' state. The developed PEC aptasensor was employed for the detection of MNPs released from food packaging materials. Although the aptasensor displayed distinct sensitivities toward PVC and PS, it demonstrated a consistent linear dynamic range of 1-200 μg mL-1 and a low detection limit of 0.1 μg mL-1. This switching-type PEC aptasensor provides a rapid, sensitive, and reliable analytical platform for the determination of MNPs in food and environmental matrices.
Related Concept Videos
Gravimetry: Inorganic And Organic Precipitating Agents
Types of Genetic Transfer Between Organisms
Types of Genetic Transfer Between Organisms
Switching of BJT
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Inorganic Nitrogen Assimilation


