A dual-mode sensing platform based on bifunctional iron-doped carbon dots for sarcosine detection
Lei Wang1, Weiping Liu2, Sikai Wang1
1School of Science, Xihua University, Chengdu 610039, China.
Abstract:
Sarcosine (SA) serves as a crucial biomarker for the diagnosis of prostate cancer, and its concentration in the body fluids of patients is strongly correlated with disease progression. Therefore, it is highly significant to develop a sensitive method for SA detection. In this study, iron-doped carbon dots (Fe-CDs) exhibiting peroxidase-like activity and bright yellow-green fluorescence were synthesized. A dual-mode sensing platform for the detection of SA was subsequently constructed based on the as-prepared Fe-CDs. Under the catalysis of sarcosine oxidase, SA underwent an oxidative reaction with molecular oxygen to produce formaldehyde and hydrogen peroxide (H2O2). The H2O2 was then decomposed by Fe-CDs with peroxidase-like activity, generating reactive oxygen species (ROS), which subsequently oxidized the colorless substrate N, N-diethyl-p-phenylenediamine sulfate (DPD) into pink-colored oxidized DPD (oxDPD). The resulting oxDPD displayed characteristic absorption peaks at 512 nm and 551 nm and concurrently quenched the fluorescence of Fe-CDs at 525 nm via fluorescence resonance energy transfer. Consequently, sensitive and quantitative detection of SA can be achieved by monitoring the reduction in fluorescence intensity and the corresponding increase in absorbance. This method demonstrates a detection limit of 0.023 μM and a linear range of 0.05-120 μM in the fluorescence mode, and a detection limit of 0.17 μM with a linear range of 1-50 μM in the colorimetric mode. Furthermore, this sensing platform was successfully applied to the quantitative detection of SA in human urine samples, with spiked recovery rates of 96.0%-109.2% for fluorescence and 91.0%-107.4% for colorimetry, highlighting its considerable potential for applications in disease diagnosis.
More Related Videos
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
The Carbon Cycle
Carbon Skeletons
The Dot Product
Dot Product
In engineering, the dot product of any two vectors is the product of the magnitudes of the vectors and the cosine of the angle between them. It is denoted by a dot symbol between the two vectors.
Consider a vehicle pulling an object along the ground using a rope. If the rope makes an angle with the horizontal axis, the work done can be calculated using the dot product of the force applied and the object's displacement.
The dot...