Related Experiment Video
Updated: May 5, 2026

A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
Deep learning-based one-stop 11C-CFT and 18F-FDG dual-tracer brain PET imaging protocol for Parkinson's disease
Xiaolin Sun1, Yuan Chang2, Xiaoyue Tan1
1PET Center, Department of Nuclear Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China.
None:
This study explored using deep learning (DL) to separate short-interval staggered 11C-CFT/18F-FDG brain PET images for Parkinson's disease, aiming to reduce scan waiting time. A total of 67 patients performing 11C-CFT and 18F-FDG brain PET scans on separate days were retrospectively enrolled. A Swin UNETR model was trained to generate pseudo 18F-FDG PET images from simulated dual-tracer sum images. The simulation assumed 18F-FDG was administered at 80, 100, 120, or 200 min (∆t) after 11C-CFT injection. Compared to actual 18F-FDG images, the pseudo images showed high visual similarity across all ∆t intervals. Low average NMSE values (∼0.0004) and high average SSIM values (0.9991-0.9993) were consistently achieved across all Δt groups. Bland & Altman analysis of the whole brain region demonstrated low average SUVR bias across all Δt groups remained within ±0.001. Region-wise correlation analysis revealed strong correlations between actual and pseudo 18F-FDG images across all Δt, with slopes ranging from 0.994 to 1.001, and all R2> 0.99. SUVmean, LBR and SNR values for pseudo 18F-FDG images exhibited no statistically significant differences compared to actual 18F-FDG images (P > 0.05). Dual-tracer PET images can be effectively separated using the DL model, yielding high-quality visual and semi-quantitative results when 18F-FDG is injected immediately after the 11C-CFT PET scan, thereby reducing patient wait time, improving patient comfort, and enhancing overall clinical efficiency.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![PET Imaging of Neuroinflammation Using [11C]DPA-713 in a Mouse Model of Ischemic Stroke](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F57243.jpg&w=3840&q=50)