A malleable mild steel probe for retrieving deeply embedded fractured burs in third molar surgery: a case report
Wusimanjiang Aierken1, Reyila Aikelanmu1, Chuntao Leng1
1Department of Stomatology, The Fifth Affiliate Hospital of Xinjiang Medical University, No. 118 Henan West Road, Urumqi, Xinjiang, 830011, China.
Background:
The retrieval of fractured high-speed handpiece burs during mandibular third molar surgery, particularly those adjacent to the mandibular canal or complicated by infection, presents a significant clinical challenge. Conventional techniques often fail in such scenarios owing to anatomical constraints and limited resources in primary care settings. This case report highlights the innovative application of a modified mild steel probe technique for managing this rare but serious complication, demonstrating its adaptability across diverse clinical environments.
Case Presentation:
We present two cases with deeply embedded bur fragments. Patient 1 involved a 28-year-old female with a 2.8-mm fragment near the mandibular canal. Using a novel, real-time shapable (≤ 120°) unquenched mild steel probe and a "three-point" localization method under panoramic radiography, the fragment was successfully retrieved in 35 min, with resolved neurosensory deficits at the 1-month follow-up. Patient 2 involved a 27-year-old female with a larger fragment (3.2 mm × 1.5 mm) complicated by infection and bone destruction. Under CBCT guidance, an upgraded probe was shaped into a 135° reverse hook and used with a "layered dissection" technique, achieving retrieval in 25 min. The patient experienced significant symptom relief by day 3 and near-complete bone regeneration at 3 months.
Conclusions:
This case report demonstrates that a malleable, non-quenched mild steel probe technique may offer a material-independent, angle-adaptive, and cost-effective alternative for retrieving deeply embedded bur fragments. Its core innovation lies in overcoming the inflexibility of conventional rigid instruments and the material limitations of magnetic systems, providing a practical solution particularly in resource-conscious settings or for non-ferromagnetic fragments.
Related Concept Videos
Retrieval
Recall involves accessing information without cues, such as during an essay test, where individuals must retrieve facts and concepts from memory unaided. Another example is remembering the name of a colleague...
ER Retrieval Pathway
The ER uses many checkpoints to prevent the entry of incorrectly folded or a resident protein as cargo onto a transport vesicle. These mechanisms...
Molar Mass
Steel Fastening Techniques
Rivets are cylindrical steel fasteners with a specially designed head. During application, rivets are heated until white-hot and then inserted through pre-drilled holes in the steel sections. A pneumatic hammer is used to shape the exposed end into a second head, securing the sections together.
Bolting is another...
Introduction to Test of Independence
The test statistic for a test of independence is similar to that of a goodness-of-fit test:
Hypothesis Test for Test of Independence
H0: The two variables (factors)...