A predictive model for postoperative delirium in patients admitted to the intensive care unit after cardiac valve
Zhizhen Shi1, Zhen Yuan1, Jiwei Cheng1
1Department of Neurology, Putuo Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China.
Introduction:
Postoperative delirium (POD) frequently occurs in patients following cardiac valve surgery in the intensive care unit (ICU), and is linked to adverse outcomes and extended hospitalization. The purpose of this study was to establish and validate a model for predicting high-risk individuals.
Methods:
This retrospective analysis enrolled adult patients who had cardiac valve surgery and subsequent ICU admission. Potential predictors were screened using LASSO logistic regression with cross-validation, followed by multivariable logistic regression, and a nomogram was developed from the final model. Model performance was assessed by receiver operating characteristic (ROC) curve analysis, calibration plots and decision curve analysis (DCA), and was benchmarked against the Sequential Organ Failure Assessment (SOFA) score.
Results:
In total, 3249 patients were analyzed, of whom 535 (16.5%) developed POD. Significant predictors identified were oxygen saturation, respiratory rate, urea nitrogen, INR, white blood cell (WBC) count, hemoglobin, SOFA score, myocardial infarction, diabetes and hyperlipidemia. The nomogram yielded AUCs of 0.766 (95% CI: 0.738-0.794) in the training cohort and 0.789 (95% CI: 0.750-0.828) in the validation cohort, showing significantly better predictive accuracy than the SOFA score (p < 0.05).
Conclusions:
The proposed model demonstrates strong predictive ability for POD in cardiac valve surgery patients and may aid clinicians in early risk stratification and targeted intervention. Further prospective validation is needed.
Related Concept Videos
Patient-centered Care
Per-Unit Sequence Models
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...
Measurement: Derived Units
Measurement: Standard Units
Predicting Molecular Geometry
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...