The Brucella abortus A19ΔfeuPΔfeuQ double-mutant is highly attenuated and confers protection in BALB/c mice
Zhiqiang Li1, Shuli Wang1, Huijun Zhang1
1College of Biology and Food, Shangqiu Normal University, Shangqiu 476000, Henan Province, China.
Abstract:
Brucellosis is a globally significant zoonotic disease that affects both animals and humans. Current vaccines against Brucella abortus (B. abortus), such as A19, suffer from several limitations, including residual virulence in animals and humans and the inability to serologically differentiate infected from vaccinated animals. Here, we describe attenuated strains that match the protective efficacy of the current vaccine but offer a substantially improved safety profile and enable differentiation from infection, addressing key limitations that have hampered current control tools. We constructed a double-gene deletion mutant (A19ΔfeuPΔfeuQ) from A19 by removing genes encoding a two-component regulatory system (TCS) located on chromosome II. The A19ΔfeuPΔfeuQ mutant exhibited a >1.5-log reduction in intracellular survival and BALB/c mice, indicating marked attenuation. Vaccination with this mutant induced significantly higher titers of IgG, and provided a 2.34-log greater reduction in bacterial burden at 4 weeks post-challenge. Additionally, the FEUP and FEUQ proteins served as specific antigens enabling serological differentiation between infected and vaccinated animals. These findings demonstrate that the highly attenuated A19ΔfeuPΔfeuQ mutant is a promising live vaccine candidate against bovine brucellosis, combining efficacy, improved safety, and diagnostic compatibility.
More Related Videos
Related Concept Videos
Transcription Attenuation in Prokaryotes
There are several different mechanisms used to attenuate transcription. In ribosome mediated...
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Protecting Self-Esteem
Fixing Double-strand Breaks


