Related Experiment Video
Updated: Feb 9, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
AI-driven 3D virtual surgical planning in total hip arthroplasty: a machine learning approach for precision implant
Li-Cheng Xi1, Bang-Qi Yang1, Lin-Hua Jiang2
1Department of Orthopaedics, Affiliated Hospital of Guilin Medical University, No. 15, Lequn Road, Xiufeng District, Guilin, 541000, Guangxi, China.
Purpose:
To explore the clinical significance of the artificial intelligence (AI)-assisted three-dimensional (3D) planning system AI-HIP in total hip arthroplasty (THA) and evaluate its accuracy and efficacy in clinical practice.
Methods:
Preoperative planning was done using the AI-HIP system in the AI group and two-dimensional (2D) template measurements in the conventional group. The two groups were compared for postoperative radiographic results, perioperative monitoring indicators, and the degree of consistency between preoperative planning and actual implant size. Postoperative Harris scores, hip joint range of motion (ROM), and Barthel index were used to evaluate clinical effectiveness.
Results:
None of the patients who ultimately completed the 6-months follow-up experienced adverse events such as hip dislocation and infection during follow-up. Compared to the conventional group, the AI group had significantly higher Harris scores (P = 0.026), hip ROM (P = 0.018), Barthel index (P = 0.042) at 6 months postoperatively, and conformity rates of the acetabular (P = 0.001) and femoral components (P < 0.001) between intraoperative application of prosthesis model and preoperative planning. Additionally, the AI group had significantly shorter operation time (P = 0.041), less intraoperative blood loss (P = 0.012), and smaller discrepancy between bilateral acetabular offset (P = 0.032) and vertical distance of hip center of rotation (P = 0.011). However, no statistically significant intergroup differences were observed for the acetabular abduction angle, anteversion angle, femoral offset and leg length discrepancy.
Conclusion:
Preoperative planning for THA using the AI-HIP system has a high accuracy rate and allows for effective reconstruction of the rotation center and acetabular offset, reduction of surgical time, and early recovery of joint function. Further research is needed to confirm its potential clinical value.
Clinical Registration Number:
ChiCTR210004826, Date:28/03/2021, https://www.chictr.org.cn/showproj.html? proj=52846 .
More Related Videos
08:40Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
Published on: April 19, 2024
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
Related Concept Videos
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
Machines
A free-body diagram of the...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Uncertainty in Measurement: Accuracy and Precision