Low-Load endoluminal navigation with a magnetically actuated medical soft microrobot
Julio Guerra1, Andrei Malchikov2, Sergey Jatsun2
1Facultad de Ingeniería en Ciencias Aplicadas, Universidad Técnica del Norte, Ibarra, Ecuador.
Abstract:
Minimally invasive endoluminal interventions increasingly rely on magnetic actuation to navigate narrow lumens while limiting wall loads. Here we present a contact-aware control framework for steering a deformable, silicone-based soft microrobot with embedded magnetic particles using an externally positioned permanent magnet. We develop a dynamic model capturing viscous drag, nonlinear frictional loads, and viscoelastic wall contact, and implement a closed-loop architecture that combines vision-based state estimation with model-based force inference while optimizing magnet orientation to regulate the force vector and normal reaction. Performance is evaluated in simulation and on a benchtop testbed across three control modes. In the nominal-case benchmark, force-plus-angle control reduced the root-mean-square tracking error from 4.8 to 2.1 mm (-56%), decreased peak tracking error from 14.6 to 8.0 mm (-45%), lowered the integrated performance index from 4.4 × 10-¹⁰ to 1.6 × 10-¹⁰ (-64%), and attenuated peak normal reaction force from 2.0 × 10- 6 to 0.8 × 10- 6 N (-60%) compared with operation without force regulation. To assess robustness, we further performed a simulation-based Monte Carlo analysis (n = 500 trials per mode) under parametric uncertainty and measurement noise, confirming that the contact-aware modes preserve their performance advantage; non-parametric tests indicated statistically significant inter-mode differences with moderate-to-large effect sizes. A trade-off analysis in the {tracking error, peak normal load} plane showed that, in the explored regime, improved tracking does not inherently require higher peak contact forces. Finally, a first-order shear-thinning surrogate suggested low sensitivity of the relative conclusions to moderate non-Newtonian effects. Overall, the results identify force-aware magnet orientation as a safety-relevant control degree of freedom for endoluminal navigation and provide a transferable control methodology for future magnetic microrobotic platforms.
Related Concept Videos
Inhaled Medications
Impact Loading
In cases of elastic deformation,...
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Distributed Loads
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
Eccentric Loading
Endocarditis III: Medical Management