Related Experiment Video
Updated: Feb 10, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
High-Resolution Ultrasound Evaluation of Common Dorsal Hand Rejuvenation Techniques: A Multicenter Study
Claudia Gonzalez1, Valeria Duque-Clavijo2, Sandra Suárez3
1Radiology, Rosario University, Bogota, COL.
Abstract:
Background Hand dorsum volumization is an increasingly used aesthetic procedure, but the ultrasonographic appearance of commonly injected materials has not been systematically described. High-resolution ultrasound with Doppler (HRUD) may provide an objective method to verify product placement and support safer, standardized hand rejuvenation. This descriptive study aimed to characterize the postprocedural high-resolution ultrasonographic features of dorsal hand volumization using commonly employed fillers and autologous fat grafting. Methods We conducted a multicenter, descriptive study at three aesthetic medicine centers in Bogotá, Colombia, and Mexico City, Mexico, between March and June 2025. Adults requesting dorsal hand volumization received hyaluronic acid, calcium hydroxylapatite (CaHA), a poly-L-lactic acid (PLLA)-hyaluronic acid mixture, a factory-prepared CaHA-hyaluronic acid hybrid filler, or autologous fat grafting. All products were injected into the subdermal plane using a standardized cannula technique. HRUD was performed at baseline, early post-procedure, and at follow-up. Baseline aging was graded using the Merz Hand Grading Scale, and outcomes were assessed at two months using the Modified Aesthetic Response Scale (MARS). Results Twelve patients were included (mean age, 56 years; range, 44-66 years; 11 women). HRUD enabled clear identification of dorsal hand anatomy and material-specific sonographic patterns: CaHA appeared as hyperechoic cloud-like bands, hybrid fillers as lobulated hyperechoic structures, hyaluronic acid as hypoechoic pseudocystic areas, PLLA-hyaluronic acid mixtures as diffuse echogenicity with linear bands, and fat grafts as elongated isoechoic structures. In all cases, injected material was located superficial to the extensor tendons, with transient postinjection vascularization observed on Doppler. No early or late complications were detected. At two months, most patients demonstrated favorable short-term aesthetic improvement. Conclusion HRUD provides a practical method for documenting dorsal hand anatomy, confirming correct subdermal placement of volumizing materials, and recognizing distinct sonographic signatures. Its use may assist experienced injectors in enhancing procedural safety and monitoring. Given the short follow-up, findings should be interpreted cautiously, and larger studies with longer follow-up are warranted.
More Related Videos
Related Concept Videos
Common Ion Effect
Hand hygiene
Hand washing...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Common Respiratory Disorders
Upper respiratory disorders impact the airways above the vocal cords, encompassing areas like the nose, sinuses, and throat. Various conditions fall under this category, including the common cold and allergic rhinitis. These disorders can stem from several causes,...
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...

