Related Experiment Video
Updated: Feb 10, 2026

Author Spotlight: Advancements in Intracardiac Echocardiography for Atrial Anatomy Assessment
Published on: June 30, 2023
Precision myectomy: Real-time on-pump intracardiac echocardiography for resection in patients with thin septa
Katherine G Phillips1, Robert G Nampi2, Mark V Sherrid3
1Department of Cardiothoracic Surgery, NYU Langone Health, New York, NY.
Objective:
During septal myectomy, once the heart is arrested and drained of blood on cardiopulmonary bypass, transesophageal echocardiography can no longer assess septal thickness. In the present study, we evaluated the effectiveness of on-pump intracardiac echocardiography (OPIE) for real-time intraoperative septal thickness assessment in patients with preoperative thickness ≤2.0 cm. Our hypothesis was that OPIE measurements would be conconcordant with the pre- and postcardiopulmonary bypass transesophageal echocardiography measurements that are at present the primary operative guides.
Methods:
We retrospectively reviewed patients with hypertrophic cardiomyopathy and septal thickness ≤2.0 cm on transthoracic echocardiography who underwent septal myectomy from July 2017 to July 2024. The OPIE probe was introduced into the left-ventricular chamber during cardioplegic arrest, with repeated measurements to assess the depth and adequacy of resection. Septal thickness was evaluated pre-myectomy using transthoracic echocardiography, cardiac magnetic resonance imaging, transesophageal echocardiography, and OPIE. Lin's concordance correlation coefficients and Bland-Altman analyses were used to evaluate agreement between modalities.
Results:
A total of 220 patients were included with preoperative thickness ≤2.0, 56 of whom underwent myectomy with OPIE guidance. Preresection transesophageal echocardiography and OPIE demonstrated the strongest agreement of all the imaging modalities (Lin's concordance correlation coefficient, 0.81; 95% CI, 0.72-0.88), with minimal bias (-0.73) and the narrowest limits of agreement (-3.76, +2.31]. OPIE-derived resection thickness estimates were tightly clustered. In the OPIE cohort, there was 1 ventricular septal defect (1.8%) and no 30-day mortality.
Conclusions:
OPIE is a reliable tool for intraoperative assessment of septal thickness, particularly in patients with mild hypertrophy.
More Related Videos
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
07:13Author Spotlight: Advancing Neonatal Cardiac Diagnostics with Echocardiography-Derived Blood Speckle Imaging
Published on: December 22, 2023
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Uncertainty in Measurement: Accuracy and Precision