Related Experiment Video
Updated: Feb 10, 2026

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
A standardized fluoroscopic method for profiling humeral rotational alignment during intramedullary nailing
Allen A Champagne1, Winthrop C Lockwood2, Matthew Brown1
1Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA.
Background:
To date, limited methods exist for intraoperative assessment of humeral rotation during intramedullary nailing. Here, we propose a standardized fluoroscopic sequence that relies on humeral bony anatomy and known retroversion between the proximal humerus, relative to the transepicondylar axis of the elbow.
Methods:
Eight paired cadaveric specimens (4/4 M/F, N = 16) were mounted to simulate intraoperative positioning. Fluoroscopic images were acquired using a standardized sequence that includes a Grashey view of the proximal humerus and a lateral of the elbow. Rolling angles for each view were recorded and a corrective index was computed by calculating the difference in angulation between the Grashey view and lateral of the elbow. To test the proposed method, a transverse fracture of the proximal humerus was induced, and rotation was set during intramedullary fixation using the proposed sequence.
Results:
Paired T-test comparing contralateral corrective indices showed no statistical difference across the paired sides (P = .190). Moreover, Pearson correlation among sides showed contralateral agreement (rho = 0.957, P = .0002) with absolute differences ranging from 1° to 8° suggesting that contralateral extremity can serve as a template for rotational profiling using this method.
Conclusion:
The proposed fluoroscopic sequence provides a standardized method to restore native rotation of the humerus during intramedullary fixation, whereby the contralateral extremity can be used as a reference.
More Related Videos
Related Concept Videos
Accessory Structures of the Skin: Nails
The main components of a nail include the following.
Nail Plate: The nail plate is the visible portion of the nail that extends beyond the fingertips or toes. It is a hard, translucent...
Empirical Method to Interpret Standard Deviation
This rule is used widely in statistics to calculate the proportion of data values...
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...
Rotation of Asymmetric Top
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...
Design Example: Alignment of a Road Line Using GIS
Calculating Standard Free Energy Changes

