AI-based detection and sizing of saccular intracranial aneurysms: a single-center retrospective validation study
Lu Zeng1, Xue-Hua Zhang1, Wen-Hao Li1
1Banan Hospital of Chongqing Medical University, Chongqing, Chongqing, China.
Background:
Imaging advantages have raised intracranial aneurysm (IA) detection rates but have also increased radiologists' workloads. Coupled with visual fatigue, this heavier burden heightens the risk of missed or erroneous diagnoses. Concurrently, artificial intelligence (AI) has shown great promise for analyzing medical images. This study aims to evaluate the diagnostic performance of AI software for IAs and to provide an initial, single-centre validation of its potential as a supportive tool in future deployment.
Methods:
Between January 2019 and September 2023, 452 patients with 544 IAs diagnosed by head and neck computed tomography angiography (CTA) who also underwent digital subtraction angiography (DSA) were included. The AI's ability to detect the presence, location, and size of IAs was recorded. Its results were compared with DSA, and the agreement between AI and radiologists in measuring IA size was evaluated.
Results:
The AI software demonstrated a sensitivity of 88.97% (95% CI [0.861-0.963]) and an accuracy of 75.04% (95% CI [0.715-0.783]) for detecting IAs. Specifically, the accuracy and sensitivity of AI in detecting IAs that are smaller than three mm, between 3-5 mm, and larger than five mm are 58.46% (95% CI [0.462-0.698]) and 66.67% (95% CI [0.537-0.775]), 76.68% (95% CI [0.714-0.813]) and 88.93% (95% CI [0.843-0.924]), 77.10% (95% CI [0.720-0.816]) and 94.24% (95% CI [0.906-0.966]), respectively. There was good agreement between radiologists and DSA, between AI and DSA, and between radiologists and AI for identifying the location of IAs, with kappa values all greater than 0.75. The radiologists and AI also showed good consistency in measuring depth, width, height, and maximum diameter, with intraclass correlation coefficients (ICCs) all greater than 0.75, except for the neck width, which had an ICC of 0.492.
Conclusions:
The AI software performs well in terms of detecting IAs that are larger than three mm and shows good agreement with radiologists in localizing positions and extracting their morphometric parameters (except for neck width measurements). The AI software has proved to be a reliable adjunct for IA detection and measurement tasks.
More Related Videos
04:08Fluorescence Angiography for Evaluation of Aneurysm Perfusion and Parent Artery Patency in Rat and Rabbit Aneurysm Models
Published on: July 24, 2019
11:07Biodegradable Magnesium Stent Treatment of Saccular Aneurysms in a Rat Model - Introduction of the Surgical Technique
Published on: October 1, 2017
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Reliability and Validity
Lattice Centering and Coordination Number
Types of Unit Cells
Imagine taking a large number of identical...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...