A Standardized Obstacle Course for Assessment of Visual Function in Ultra Low Vision and Artificial Vision
Published on: February 11, 2014
Visual Function Loss Through Opacified Media: Comparison Between Single- and Two-Photon Vision
Ava Niknahad1,2, Agnieszka Zielinska1,3, Hyeck-Soo Son1
1The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany.
Purpose:
The purpose of this study is to quantify the effect of monofocal intraocular lens (IOL) turbidity on visibility threshold and spatial pattern detection threshold with an infrared (IR)-two-photon (2P) approach, and visible light.
Methods:
Three observers were tested with pulsed IR (1045 nm) and visible lights (522.5 nm) using visibility threshold and spatial pattern detection threshold methods on two clear control IOLs and 11 explanted opacified IOLs, using our 2P microperimetry setup. IOL power and straylight were measured. Data from the clear IOLs served as control.
Results:
Control IOLs (20 D) had a mean straylight of 0.57 ± 0.05 logs and opacified IOLs (18.9-21.8 D) had a mean straylight of 2.16 ± 0.37 logs. Most threshold measurements differed significantly between clear and opacified IOLs. For IR, slopes of linear regression of straylight vs. visibility threshold and spatial pattern detection threshold ratios were similar (0.78 vs. 0.93 logs-1; P = 0.8531). For visible light, the visibility threshold ratio slope was lower than the spatial pattern detection threshold ratio (2.97 vs. 4.53 logs-1; P = 0.0008). IR measurements showed significantly less dependence on straylight than visible light for both visibility threshold and spatial pattern detection threshold (P < 0.00001).
Conclusions:
We found that 2P measurements yield lower variability and reduced straylight dependence compared with visible light with either the spatial pattern detection threshold or visibility threshold methods.
Translational Relevance:
Regardless of spatial pattern detection threshold or visibility threshold methods, two-photon microperimetry is less affected by increased opacity and may yield consistent threshold ratio results.
Related Concept Videos
Loss of Tumor Suppressor Gene Functions
When the tumor suppressor genes develop mutations or are lost, cells start growing out of control, leading to cancer. However, a single functional copy of the tumor suppressor gene is enough for the cells to maintain their normal functions and cell...
Vision
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Color Vision
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...