Contrast-Enhanced Mammography-Guided Biopsy for MRI-Detected Breast Lesions: A Prospective Study
Yuying Cao1, Amy H Lu2, Ryan Cecil3
1School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA.
Contrast-enhanced mammography biopsy (CEM-Bx) successfully targets MRI-suspicious breast lesions lacking other imaging correlates. Factors like lesion size and radiologist experience influence CEM-Bx success rates.
Area of Science:
- Radiology
- Breast Imaging
- Interventional Radiology
Background:
- MRI is crucial for detecting breast lesions, but biopsy guidance can be challenging for lesions without sonographic or tomosynthetic correlation.
- Contrast-enhanced mammography biopsy (CEM-Bx) offers a potential alternative for these difficult-to-biopsy lesions.
Purpose of the Study:
- To evaluate the success rate of CEM-Bx for MRI-detected breast lesions without tomosynthesis or ultrasound correlation.
- To identify factors associated with successful CEM-Bx in this patient cohort.
Main Methods:
- A prospective study included women with BI-RADS ≥4A MRI lesions undergoing CEM-Bx.
- CEM was performed, followed immediately by CEM-Bx if a correlate was visualized.
- Success was defined by visualization of an enhancing correlate and accurate lesion sampling; failures proceeded to MRI-guided biopsy.
Main Results:
- CEM-Bx was successful in 57.6% of 184 lesions across 152 women.
- Malignancy was found in 22.6% of successful biopsies and 17.9% of failures.
- Factors associated with CEM-Bx success included larger lesion size, increased radiologist CEM experience, and lower background parenchymal enhancement (BPE).
Conclusions:
- CEM-Bx is a viable alternative to MRI-guided biopsy for specific MRI-detected breast lesions.
- MRI-guided biopsy remains essential for cases where CEM-Bx is unsuccessful.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Self-Evaluation: Self-Enhancement and Self-Verification
Bioavailability Enhancement: Drug Solubility Enhancement
Bioavailability Enhancement: Drug Permeability Enhancement
Bioavailability Enhancement: Drug Stability Enhancement and GI Retention