Multiplex Cryoimmunostaining in Fine-Needle Aspiration Biopsies and Effusion Samples: Preliminary Results
Simona Miceska1, Ivana Kholová2,3,4, Veronika Kloboves Prevodnik5,6
1Department of Cytopathology, Institute of Oncology Ljubljana, Ljubljana, Slovenia.
None:
Introduction: Immunocytochemistry (ICC) on cytospins and cell blocks is usually limited to a single marker per slide, often restricting diagnostic accuracy when sample cellularity is low. Multiplex cryoimmunostaining (mCryo), though not yet used in a routine cytopathology practice, may help overcome these limitations. Our study evaluated the applicability of mCryo compared with standard ICC on routinely prepared cytospins.
Methods:
Residual fine-needle aspiration biopsy and effusion samples from various diseases were used. mCryo staining with antibody panel consisting of EpCAM, CK7, CD56, TTF-1, p40, CD45, and calretinin (X-ZELL, Singapore) was tested on methanol-fixed cytospins, corresponding ICC-stained cytospins served as controls. All slides were reviewed blindly.
Results:
Forty-two samples were included in the analysis (21 carcinomas, eight lymphomas, five melanomas, eight non-neoplastic). mCryo revealed preserved morphology and no background staining in most of the cases. A 100% of true positivity was observed for EpCAM (21/21), CK7 (21/21), p40 (3/3), and TTF-1 (1/1) in carcinomas matching ICC results. TTF-1 was also true-positive in 2/2 benign thyroid nodule samples. CD45 was detected in all samples with both methods, labeling lymphocytes. Calretinin was true-positive only in 2/6 effusion samples. CK7 positivity was unexpectedly detected in all melanomas (5/5) by mCryo but not by ICC. Moreover, CD56 was also positive in all carcinomas and melanomas by mCryo (26/26), while only 9 cases were positive by ICC, raising the question of unspecific staining, antibody cross-reactivity, or spectral overlap of fluorochromes.
Conclusions:
mCryo enables simultaneous evaluation of multiple markers per slide on routinely prepared cytospins, offering potential diagnostic advantages for paucicellular samples. However, further method and panel improvement, and validation are essential for accurate diagnostic implementation into routine practice.
.Related Concept Videos
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion
Pleural Effusion I: Introduction
There are two main types of pleural effusion: transudative and exudative. They are differentiated using Light's...
Pleural Effusion II: Symptoms and Management
A pleural effusion is the abnormal collection of fluid between the parietal and visceral pleura layers of tissue that form the lining of the lungs and chest cavity. It can occur independently or due to surrounding parenchymal diseases, such as infection, malignancy, or inflammatory conditions.
Clinical Manifestations:
Fineness of Cement
Direct...
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...