Monte Carlo simulations of a new 3D electronic detector for radiotherapy quality assurance
Mirko Salomón Alva-Sánchez1, Renzo Aaron Ocampo Burga2, Dante Roa3,4
1Federal University of Health Sciences of Porto Alegre, Porto Alegre, Brazil.
Abstract:
Objective. Evaluate the dosimetric performance of a novel three-dimensional (3D) electronic detector array for radiotherapy quality assurance using Monte Carlo simulations.Approach. Monte Carlo simulations were performed with Geant4 and MCNP6.2. A detailed detector model (MCModel) was implemented consisting of a 50 × 50 × 50 cm3polymethyl methacrylate (PMMA) phantom with 20 imbedded active matrices (AMs) at strategic depths, 1169 pixels per AM, and 23 380 pixels for the entire detector. A pixel comprises a diode, capacitor, and MOSFET, where the diode elements provide a 42 × 42 cm2sensitive area within an AM. Photon beam energy spectra of 6 MV and 10 MV, respectively, of a Varian radiotherapy linear accelerator (linac) were used in the simulations. Dosimetric data consisting of per cent depth-doses (PDDs) and cross-/in-plane profiles for field sizes of 5 × 5 cm2through 40 × 40 cm2were simulated for the MCModel, and a homogeneous PMMA phantom (MCPMMA) of similar dimensions.Main results.MCModelversus MCPMMAPDD data difference for Geant4 and MCNP6 were within 3.44% and 3.83%, while profiles (cross-/in-plane) were within 5.54% and 5.68%, for all field sizes and energies.Significance. These results suggest that a 3D electronic detector could provide suitable dosimetric data for radiotherapy QA, and if realised, it could likely provide it in less time than current methods.
More Related Videos
Related Concept Videos
Quality Assurance
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Electron Affinity