Effects of reduced kVp and contrast volume on dose and image quality in canine abdominal CT
Sumin Kim1, Gunha Hwang1, Tae Sung Hwang2
1Institute of Animal Medicine, College of Veterinary Medicine, Gyeongsang National University, Jinju 52828, Korea.
Importance:
Lower peak kilovoltage (kVp) can reduce radiation dose and increase iodine conspicuity, but veterinary CT protocols integrating kVp reduction with iodine-dose reduction are not well defined.
Objective:
To evaluate the effects of reduced kVp and reduced iodinated contrast volume on radiation dose and image quality in canine abdominal CT.
Methods:
A phantom study (0%-10% iodine dilutions) at 120, 100, and 80 kVp quantified the relationship between iodine concentration and CT attenuation. Eight healthy Beagle dogs underwent multiphase abdominal CT at 120, 100, and 80 kVp (1-week intervals) with weight-based contrast volumes adjusted using phantom-derived slope ratios. Radiation output (CTDIvol, dose-length product) and quantitative image quality (attenuation, background noise, signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR]) were assessed, along with blinded qualitative scoring by 2 readers.
Results:
Compared with 120 kVp, CTDIvol decreased by 41% at 100 kVp and 74% at 80 kVp, with similar proportional decreases in dose-length product. Lower kVp increased iodine-related attenuation, permitting iodine-dose reductions (17% at 100 kVp; 34% at 80 kVp). Quantitative noise increased and SNR decreased at 80 kVp, particularly in delayed-phase images; qualitative noise scores were significantly worse at 80 kVp, whereas overall qualitative image quality did not differ across protocols.
Conclusions And Relevance:
In dogs, a 100 kVp protocol reduced radiation output and iodine dose while maintaining diagnostic image quality, supporting 100 kVp as a practical optimization strategy for clinical abdominal CT.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Abdominal Aorta
The celiac trunk, a singular artery, divides into the left gastric artery, which...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...