Related Experiment Video
Updated: Feb 11, 2026

Development of an Electrochemical DNA Biosensor to Detect a Foodborne Pathogen
Published on: June 3, 2018
Artificial neural network modeling and optimization of an electrochemical biosensor for plasma miR-155-based breast
Aydin Imani1, Soleiman Hosseinpour2, Mostafa Azimzadeh3
1Faculty of Agricultural Engineering and Technology, University of Tehran, Karaj, Iran. Imani.aydin@yahoo.com.
Abstract:
MicroRNA-155 (miR-155) is a clinically important biomarker involved in cancer progression, immune regulation, and inflammatory diseases, highlighting the need for sensitive and reliable detection methods. Conventional biosensor fabrication often relies on labor-intensive trial-and-error optimization, which delays the development of practical diagnostic tools. In contrast to most previous studies that focus on predicting analyte concentration from biosensor signals, this work develops a data-driven framework for modeling the nonlinear relationships between fabrication parameters and biosensor output. Artificial neural networks (ANN) and adaptive neuro-fuzzy inference systems (ANFIS) were proposed to model a voltammetric biosensor for plasma miR-155 detection. A dataset containing the biosensor output current and six fabrication parameters was used. The optimal parameter values were determined using a genetic algorithm (GA). The results show that the ANN approach outperforms ANFIS, achieving an [Formula: see text] value of 0.9845. The optimal fabrication parameters were 7.12 nM, 85.22 min, 6.54 min, 118.02 min, 0.12 mM, and 93.39 min for detection probe concentration, detection probe incubation time, MCH incubation time, hybridization time, OB concentration, and OB incubation time, respectively, resulting in an output current of 223 nA. The ANN-GA framework offers a practical and efficient strategy for biosensor development by reducing experimental iterations, thereby lowering material consumption and enabling rapid parameter optimization. These findings demonstrate that ANN-assisted optimization can accelerate the development of cost-effective, high-performance biosensors, supporting their translation into clinical diagnostics for early and accurate miR-155 detection.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Protein Networks
These interactions can be represented through maps depicting protein-protein interaction networks, represented as nodes and edges. Nodes are circles that are representative of a protein,...
Network Covalent Solids
To break or to melt a covalent network solid, covalent bonds must be broken. Because covalent bonds are relatively strong, covalent network solids are typically...
Neural Regulation
Optimal Foraging
Natural and Artificial Concepts