Related Experiment Video
Updated: Feb 11, 2026

Robotic Myotomy and Partial Fundoplication for Achalasia
Published on: August 11, 2023
High-Resolution Impedance Manometry (HRIM) Using Yogurt (Viscosity Matched to Barium) for Bolus Clearance After
Abhijeet Karad1, Sridhar Sundaram1, Suprabhat Giri1
1Department of Gastroenterology, Seth GS Medical College, King Edward Memorial Hospital, Acharya Donde Marg, Parel, Mumbai, 400012, India.
Objective:
Timed-barium esophagogram (TBE) is established test for assessing bolus clearance in achalasia post-treatment. However, radiation exposure is an important disadvantage. Esophageal bolus transit can be evaluated by HRIM. Previous studies comparing Impedance bolus height (IBH) using saline and TBE showed fair correlation. We compared bolus clearance by TBE versus HRIM using yogurt (viscosity matched to barium-calculated using Ostwald viscometer) in patients treated for achalasia.
Methods:
HRIM was performed using solid-state system (MMS, Netherlands). Twenty patients (age 45.1 years; 8 men) treated with pneumatic dilatation (Rigiflex, Boston Scientific) were evaluated with TBE (200 ml Barium) and HRIM (200 ml yoghurt) two weeks after dilation. Both tests were performed in upright position. Barium column height and impedance bolus height (IBH) were measured at 0, 1 and 5 min. Analysis of IBH was performed with spatial impedance variation plot overlayed on esophageal pressure topography. All patients gave consent, and protocol was approved by the IRB.
Results:
At baseline, 5, 11 and 4 patients had type I, II and III achalasia, respectively. Eckardt score showed an improvement of 5 (range 1-9) points. The mean column height as measured by IBH and TBE at 5 min was similar (4.6 [range 0-12.5] cm vs. 4.25 [0-16] cm). Pearson correlation between the TBE column and IBH was 0.73 at 5 min. Bland Altman plot for bolus clearance as measured by TBE and HRIM showed good agreement between the modalities.
Conclusions:
There is good agreement between HRIM (performed using yoghurt) and TBE for evaluation of bolus clearance after therapy in achalasia patients. Single HRIM study done with viscosity matched liquid to barium can give information about bolus clearance and motor function in treated achalasia patients, avoiding radiation exposure.
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Viscosity
The SI unit of viscosity is...
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Viscosity of Fluid
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...

