Related Experiment Video
Updated: Feb 11, 2026

Automation of a Positron-emission Tomography PET Radiotracer Synthesis Protocol for Clinical Production
Published on: October 26, 2018
Corrigendum: Short-lived positron emitters in beam-on PET imaging during proton therapy (2015Phys. Med. Biol.608923)
P Dendooven1,2, H J T Buitenhuis1, F Diblen1,3
1KVI-Center for Advanced Radiation Technology, University of Groningen, Zernikelaan 25, 9747AA Groningen, The Netherlands.
Abstract:
Because of strong indications of multiple counting by the multi-channel scaler (MCS) during most of the experiments described in Dendoovenet al(2015Phys. Med. Biol.608923-47), the production of short-lived positron emitters in the stopping of 55 MeV protons in water, carbon, phosphorus and calcium was remeasured. The new results are reported here. With proper single counting of the MCS, the new production rates are 1.1 to 2.9 times smaller than reported in Dendoovenet al(2015Phys. Med. Biol.608923-47). The omission of the conversion from MCS time bin to time unit in the previous data analysis was corrected, leading to an increase of the production rate by a factor of 2.5 or 10 for some nuclides. The most copiously produced short-lived nuclides and their production rates relative to the relevant long-lived nuclides are:12N (T1/2 = 11 ms) on carbon (5.3% of11C),29P (T1/2 = 4.1 s) on phosphorus (23% of30P) and38mK (T1/2 = 0.92 s) on calcium (173% of38gK). The number of decays integrated from the start of an irradiation as a function of time during the irradiation of PMMA and 4 tissue materials has been determined. For (carbon-rich) adipose tissue,12N dominates up to 70 s. On bone tissue,38mK dominates the beam-on PET counts from 0.2-0.7 s until about 80-110 s. Considering nuclides created on phosphorus and calcium, the short-lived ones provide 8 times more decays than the long-lived ones during a 70 s irradiation. Bone tissue will thus be much better visible in beam-on PET compared to PET imaging after an irradiation. From the estimated number of12N PET counts, we conclude that, for any tissue, except carbon-poor ones,12N PET imaging potentially provides equal quality proton range information as prompt gamma imaging with an optimized knife-edge slit camera.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Short-distance Transport of Resources
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Proton (¹H) NMR: Chemical Shift