Functional Outcomes and Early Complications Following Volar Locking Plate Fixation of Unstable Distal Radius
1Orthopaedics, Naresuan University, Phitsanulok, THA.
Abstract:
Background Volar locking plate fixation has become the preferred operative treatment for unstable distal radius fractures because it allows stable fixation and early mobilization. However, long-term clinical outcomes and early complications in Asian populations treated in routine practice remain less well documented. Methods This retrospective cohort study included 40 consecutive adult patients with unstable distal radius fractures treated with volar locking plates by a single hand and wrist surgeon at a university hospital between January 2012 and December 2021. Patients met predefined radiographic criteria for instability and were followed for at least two years. Radiographic parameters (radial inclination, palmar tilt, and ulnar variance) were assessed preoperatively, immediately after surgery, at three months, and at ≥2 years. Wrist range of motion, grip strength, Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH), Patient-Rated Wrist Evaluation (PRWE), and pain visual analog scale (VAS) scores were recorded preoperatively, at two weeks, three months, and at ≥2 years. Early complications within three months (carpal tunnel syndrome, median nerve palmar branch injury, and extensor pollicis longus rupture) were retrieved from medical records. Paired t-tests were used to compare changes over time. Results A total of 40 patients were included (mean age, 55.4 years), of whom 26 (65.0%) were women. Radiographic alignment improved after fixation and was maintained at ≥2 years. Patient-reported outcomes (QuickDASH and PRWE), pain, range of motion, and grip strength improved progressively, with minimal disability and pain at long-term follow-up. Early symptoms consistent with carpal tunnel syndrome occurred in seven (17.5%) patients; no median nerve palmar branch injury, extensor pollicis longus rupture, or flexor pollicis longus rupture was identified. Conclusions In this single-surgeon retrospective cohort with a minimum two-year follow-up, volar locking plate fixation for unstable distal radius fractures achieved durable restoration of radiographic alignment and progressive improvement in wrist-related pain and function. Patient-reported outcomes, range of motion, and grip strength improved over time, and major complications were uncommon; early symptoms consistent with carpal tunnel syndrome occurred in seven (17.5%) patients, and no extensor pollicis longus or flexor pollicis longus rupture was identified. Overall, these findings support volar locking plate fixation as a reliable treatment option for unstable distal radius fractures in routine clinical practice.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
Related Concept Videos
Radius of Gyration of an Area
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Schwarzschild Radius and Event Horizon
The minimum speed required to launch a projectile from the surface of an object to which it is gravitationally bound so that it eventually escapes the object’s gravitational field is called the escape velocity. The escape velocity is independent of the mass of the object. Merging the idea of escape...
Degree of Curvature and Radius of Curvature
Hemodialysis II: Procedure and Complications
