Related Experiment Video
Updated: Feb 11, 2026

Cardiac Magnetic Resonance Imaging at 7 Tesla
Published on: January 6, 2019
Cardiac meshes reconstruction from cardiac magnetic resonance image by graph transformation
Yang He1,2, Yurun Yang2, Dong Liang1,2
1School of Biomedical Engineering, Southern Medical University, Guangzhou, China.
Background:
Reconstructing 3D patient-specific cardiac meshes from cardiac magnetic resonance (CMR) images remains a challenging task due to low through-plane resolution, inter-slice misalignment, and anatomic variability. Conventional reconstruction methods often suffer from topological inaccuracies and stair-step artifacts, whereas deep learning-based approaches are constrained by high computational demands and the scarcity of labeled mesh data.
Purpose:
We propose a novel graph transformation-based method for reconstructing 3D cardiac meshes from 2D cine images.
Methods:
By reconstructing mesh vertex displacement with frequency analysis through graph Fourier transform (GFT) and graph wavelet transform (GWT), our method leverages different frequency components to capture cardiac shape features at various scales. Furthermore, we introduce a temporal loss in dynamic mesh reconstruction to ensure physiological consistency in the temporal direction.
Results:
Extensive experiments were conducted on the public ACDC dataset and a private CMR dataset. The results demonstrate that the proposed method outperforms state-of-the-art approaches in both reconstruction accuracy and mesh quality. Ablation studies further highlight the pivotal role of the GWT in capturing fine anatomical structures and the effectiveness of the temporal loss.
Conclusions:
Our framework eliminates the reliance on labeled mesh data and enables high-fidelity reconstruction of patient-specific cardiac meshes.
More Related Videos
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
12:24Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse
Published on: June 20, 2014
Related Concept Videos
Magnetic Resonance Imaging
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Imaging Studies IV: Magnetic Resonance Imaging
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...