Related Experiment Video
Updated: Feb 12, 2026

Detection of Human Leukocyte Antigen Biomarkers in Breast Cancer Utilizing Label-free Biosensor Technology
Published on: March 24, 2015
Exogenous-Label-Free Colorimetric/SERS Dual-Mode Immunosensing Platform Driven by Au NCs@Pt Nanozyme for
Qian-Jiao Qi1, Zhen Xu2, Yi-Fan Yu1
1College of Energy, College of Chemistry and Chemical Engineering, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Materials, School of Life Sciences, Institute of Artificial Intelligence, State Key Laboratory of Vaccines for Infectious Diseases, Xiang An Biomedicine Laboratory, Xiamen University, Xiamen 361005, China.
Abstract:
Early diagnosis of pancreatic cancer is critical for improving survival rates, yet conventional CA19-9 immunoassays and labeled surface-enhanced Raman scattering (SERS) methods are often limited by slow processing, complex fabrication, or instability. Herein, we report a rapid, exogenous-label-free colorimetric/SERS dual-mode sandwich immunoassay utilizing coral-like gold nanocores decorated with platinum clusters (Au NCs@Pt). This unique nanozyme architecture synergistically integrates high-density electromagnetic hotspots with efficient peroxidase-like activity to catalyze the oxidation of TMB. The resulting oxidized product (oxTMB) acts as an intrinsic Raman reporter, eliminating the need for exogenous labels and enabling catalysis-amplified signal reporting. The proposed platform achieves quantitative CA19-9 detection within 15 min, featuring a linear range of 1-200 IU/mL and an ultralow limit of detection (LOD) of 0.16 IU/mL. Clinical validation using 60 serum samples demonstrated 100% diagnostic accuracy (AUC = 1.00 in this cohort study). This strategy successfully overcomes the limitations of traditional SERS tags, offering a robust, ultrasensitive tool for the point-of-care screening of digestive system malignancies.
Related Concept Videos
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Modes of Standing Waves - I
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....
MOSFET: Enhancement Mode
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...

