PSMA-RADS 2.0: clinical validation and technical considerations for prostate-specific membrane antigen positron
Luyi Cheng1, Chaobo Jin1, Huai Zhang1
1Department of Nuclear Medicine, The Affiliated Huaian No. 1 People's Hospital of Nanjing Medical University, Huai'an, China.
Background:
The updated diagnostic framework prostate-specific membrane antigen Reporting and Data System 2.0 (PSMA-RADS 2.0) has been introduced as a standardized scoring system for PSMA positron emission tomography/computed tomography (PET/CT) structured reporting to enhance the accuracy and clinical utility of prostate cancer (PCa) lesion interpretation. This study aims to evaluate the reliability and identify potential limitations of PSMA-RADS 2.0 in clinical applications.
Methods:
We conducted a comparative analysis between PSMA-RADS versions 1.0 and 2.0, followed by prospective evaluation of 109 lesions using PSMA-RADS 2.0 criteria. Inter- and intra-reader consistencies were analyzed statistically to evaluate the reliability and practicality of the scoring system. In the context of two independent readings, the inter-reader consistency between experienced readers (ERs) and inexperienced readers (IRs) was evaluated using the intra-class correlation coefficient (ICC).
Results:
Compared to version 1.0, PSMA-RADS 2.0 simplified primary PSMA-RADS-1 classification for Category I lesions and introduced PSMA-RADS-5T for post-treatment assessment. Inter-reader correlation coefficients values demonstrated excellent consistency (ERs: 0.964-0.969; IRs: 0.929-0.932). Intra-reader correlation coefficients ranged from 0.920 to 0.985 across all readers. However, challenges persisted in lymph node interpretation (ICC: 0.797-0.823) and post-treatment classification.
Conclusions:
PSMA-RADS 2.0 provides a reliable framework for PSMA PET/CT interpretation, even for IRs. Further refinement is needed for post-treatment categorization and lymph node differentiation. The proposed PSMA-RADS-5T sub-classification complete remission/partial remission/stability disease/progression disease (CR/PR/SD/PD) may enhance clinical utility for treatment monitoring.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Emission Spectra
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...