Related Experiment Video
Updated: Feb 12, 2026

Acute Myocardial Infarction in Rats
Published on: February 16, 2011
Antibody-Oriented Engineering Enables Rapid and Ultrasensitive SERRS-Based Detection of Cardiac Troponin T for Acute
Jun-Jie Wu1, Shanshan Xu2, Jia-Sheng Lin1
1College of Energy, College of Chemistry and Chemical Engineering, State Key Laboratory of Physical Chemistry of Solid Surfaces, School of Life Sciences, Discipline of Intelligent Instrument and Equipment, Institute of Artificial Intelligence, Xiamen Cardiovascular Hospital of Xiamen University, School of Medicine, State Key Laboratory of Vaccines for Infectious Diseases, Xiang An Biomedicine Laboratory, Xiamen University, Xiamen 361005, China.
Abstract:
Acute myocardial infarction (AMI) is a leading global cause of death with a sudden onset, which necessitates rapid and accurate diagnosis for effective treatment. However, existing detection methods for emergency scenarios (e.g., ambulances) suffer from limited sensitivity and high cost, hindering their widespread application. To address this unmet clinical need, we developed a rapid and highly sensitive immunoassay platform based on surface-enhanced resonance Raman scattering (SERRS) for the quantitative detection of cardiac troponin T (cTnT), the gold-standard biomarker for AMI. This platform exhibits several advances. First, an antibody-oriented engineering strategy combined with core-shell SERRS nanotag synthesis fully exposes the antibody Fab regions to improve antigen-binding efficiency while reducing the nanotag cost by up to 75%. Meanwhile, selection of the resonance Raman reporter IR-808, which matches the 785 nm laser excitation wavelength, significantly enhances the detection signal intensity and sensitivity. Integrating these advantages with the classic sandwich immunoassay structure, the assay achieves a remarkable limit of detection of 0.24 pg/mL within only 7 min. Furthermore, systematic optimization of the incubation buffer (including pH value, surfactants, and blocking agents) effectively minimizes nonspecific adsorption, enabling 100% accurate differentiation between cTnT-positive and negative human serum samples. Collectively, this sensitive, rapid, and cost-effective platform demonstrates great potential for AMI point-of-care testing and prognosis monitoring.
Related Concept Videos
Location and Orientation of the Heart
What is Genetic Engineering?
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Methods of Documentation I: Source-Oriented Records
In an SOR, each discipline involved in patient care maintains a separate medical record section. This record-keeping method enables easy tracking of patient progress and ensures healthcare staff have access to up-to-date information.
Key Attributes include the following: