Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
Determinants of variability in repeated auscultatory blood pressure measurements
Shingo Yamashita1,2, Kei Asayama3, Nobuki Yakura2
1Cooperative Major in Advanced Biomedical Sciences, Graduate School of Advanced Science and Engineering, Waseda University, Shinjuku.
Objective:
Auscultation is the reference standard for validating automated blood pressure monitoring. However, its inherent variability may compromise validation reliability. This study aimed to quantify the variability in repeated auscultatory measurements and determine the relative contributions of the underlying factors.
Methods:
Data were analyzed from an accuracy validation study ( n = 85) conducted under the International Organization for Standardization 81060-2 : 2018+Amd 1 : 2020 standard, wherein two trained observers performed simultaneous auscultatory measurements. Using the Guide to the Expression of Uncertainty in Measurement framework, the total variability of repeated auscultatory measurements was decomposed into the proportional contributions of the blood pressure determination methodology (inherent uncertainty of identifying Korotkoff sounds during cuff deflation), observer, and participant.
Results:
A total of 85 participants (55.3% female), including 13 receiving antihypertensive medications, were analyzed. The mean age was 59.5 ± 10.2 years. Mean systolic/diastolic blood pressure were 124.9 ± 24.1/76.5 ± 14.2 mmHg. Repeated auscultatory measurements showed variability with SDs of 4.91 mmHg for systolic and 3.26 mmHg for diastolic blood pressure ( n = 255). The analysis identified methodology as the largest contributor to variability (systolic: 47.4%, diastolic: 46.0%), while observer and participant factors contributed less (systolic: 5.3% and 7.1%; diastolic: 16.4% and 6.8%).
Conclusion:
Substantial variability exists in auscultatory blood pressure measurements, even when performed under the International Organization for Standardization standard, with the determination methodology being the primary source. Our findings suggest that the inherent variability of the auscultatory method should be acknowledged as a limiting factor in identifying accurate blood pressure in clinical and research settings.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...