Related Experiment Video
Updated: Feb 12, 2026

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Optimization and Validation of the SBSE-HPLC-FLD Method for the Determination of Priority Pollutants PAHs in Several
Eduardo Fernandes-Lage1,2, Maria José Alves3,4,5, Cosme Moura6
1AquaValor - Centro de Valorização e Transferência de Tecnologia da Água - Associação, Rua Dr. Júlio Martins n.º 1, 5400-342, Chaves, Portugal. Eduardo.lage@aquavalor.pt.
Abstract:
Polycyclic aromatic hydrocarbons (PAHs) are priority pollutants in drinking and environmental waters. Their mutagenic/carcinogenic potential and ng·L- 1 limits demand methods that are both sensitive and practical. We report a rapid, solvent-sparing workflow coupling stir-bar sorptive extraction (SBSE) to HPLC with fluorescence detection (FLD) for simultaneous determination of six PAHs (fluoranthene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, benzo[ghi]perylene, indeno[1,2,3-cd]pyrene) in drinking water, groundwater, and surface water. SBSE conditions were optimized, and isocratic RP-HPLC achieved baseline resolution within a 26-min cycle using ~ 39 mL solvent (~ 20 samples day - 1). Validation under ISO/IEC 17,025 showed linear calibration (r ≥ 0.99941), limits of detection of 0.4-1.8 ng·L- 1, and matrix-verified LOQs of 1.5-10.9 ng·L- 1. Trueness and precision met predefined criteria across matrices (recoveries 63.3-109.9%; within-laboratory reproducibility ≤ 25% RSD), with expanded uncertainties U(k = 2) ≤ 47.1%. Performance satisfies EU Drinking Water Directive 2020/2184 requirements for benzo[a]pyrene and the regulated PAH sum. By attaining sub-10 ng·L- 1 LOQs with FLD alone and documenting a complete uncertainty budget, this procedure offers a cost-effective alternative to LC-MS/MS for routine compliance and surveillance. The validated SBSE-HPLC-FLD protocol is fit-for-purpose for regulatory laboratories and environmental services requiring sensitive, robust, and scalable PAH determination across diverse water matrices.
More Related Videos
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
08:21Optimized Procedure for Determining the Adsorption of Phosphonates onto Granular Ferric Hydroxide using a Miniaturized Phosphorus Determination Method
Published on: May 18, 2018
Related Concept Videos
Reliability and Validity
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
Determining the pH of Salt Solutions