A Spin-Tip Enrichment Strategy for Simultaneous Analysis of N-Glycopeptides and Phosphopeptides from Human Pancreatic Tissues
Published on: May 4, 2022
A fully automated high-throughput system for simultaneously enriching and separating intact glycopeptides
Zhonghan Hu1, Rong Liu2, Junhui Li2
1Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass spectrometry and Clinical Application, Ningbo University, Ningbo 315211, PR China; Zhenhai Institute of Mass Spectrometry, Ningbo 315211, PR China; School of Marine science, Ningbo University, Ningbo 315211, PR China.
A new automated system, AutoGP 2, enhances glycopeptide analysis by enabling simultaneous enrichment and separation. This high-throughput glycoproteomics tool improves sample analysis efficiency and reproducibility for clinical studies.
Area of Science:
- * Proteomics and Glycomics
- * Analytical Chemistry
- * Automation and High-Throughput Systems
Background:
- * Glycopeptide analysis is crucial for understanding biological processes.
- * Existing methods for glycopeptide enrichment and separation can be time-consuming and limit throughput.
- * There is a need for automated, high-throughput solutions for large-scale glycoproteomic studies.
Purpose of the Study:
- * To develop an improved, fully automated high-throughput system (AutoGP 2) for simultaneous enrichment and separation of intact glycopeptides.
- * To evaluate the performance, including throughput, sensitivity, and reproducibility, of the AutoGP 2 system.
- * To demonstrate the system's suitability for large cohort clinical glycoproteomic sample analysis.
Main Methods:
- * Introduction of a second 10-port valve to the existing AutoGP system to enable simultaneous processing.
- * Systematic evaluation of optimal operating parameters for the AutoGP 2 system.
- * Assessment of intra-day and inter-day reproducibility using 24-hour and 15-day stress tests.
- * Coupling AutoGP 2 with a high-resolution Orbitrap mass spectrometer.
Main Results:
- * AutoGP 2 significantly improves sample analysis throughput compared to the previous AutoGP system.
- * Over 560 site-specific glycans were identified from 1 μg peptide mixture with median CV of 10.8% in triplicate analyses.
- * The instrument's duty cycle increased from 55% to 80%, saving 166 minutes per two-sample analysis.
- * Demonstrated outstanding sensitivity and reproducibility.
Conclusions:
- * AutoGP 2 is a highly effective automated system for simultaneous enrichment and separation of intact glycopeptides.
- * The system offers significant improvements in throughput, sensitivity, and reproducibility for glycoproteomics.
- * AutoGP 2 is well-suited for large-scale clinical glycoproteomic sample analysis and sample-limited studies.
Related Concept Videos
Separation of Sister Chromatids
At the onset of anaphase, separase, a proteolytic enzyme, is...
Separable Differential Equations
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Overview Of Cell Separation And Isolation
Distribution Reliability and Automation
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...