Factors Influencing Apical Extrusion of 2 Types of Endodontic Sealers with Different Delivery Systems
Shumaila Iqbal1, Nicholas S Adams1, Josette Camilleri1
1School of Dentistry, College of Medicine and Health, University of Birmingham, Birmingham, United Kingdom.
Introduction:
Comparison of the apical sealer extrusion of BioRoot RCS and BioRoot Flow and assessment of the influence of procedural and anatomical factors that contribute to extrusion.
Methods:
Human mandibular premolars were divided into 2 groups based on apical gauges (<40, >40). Other variables included the presence and size of an apical lesion (2, 4, and 6 mm), canal moisture (dry and wet), pumping and no-pumping action, and sealer tip insertion depth for BioRoot Flow (coronal vs apical). The extruded material was weighed in grams using an analytical balance to the accuracy of 0.0001 g. Statistical analysis included the Kruskal-Wallis test, Mann-Whitney U test, and multivariate linear regression to identify statistically significant factors related to sealer extrusion.
Results:
Sealer extrusion was observed in 86.8% of 288 variables tested. BioRoot Flow had significantly higher extrusion across all categorical variables compared to BioRoot RCS (P < .001). Key factors associated with increased extrusion included wet canals (P < .001), larger apical gauge (>40; P < .05), apical sealer placement (P < .005), and pumping action (P < .05). Among all variables, canal moisture was the most consistent contributor to sealer extrusion. The presence of a 6 mm apical lesion combined with an apical gauge of >40 in a wet canal with apically placed BioRoot Flow increased the risk of sealer extrusion.
Conclusions:
Wet canals, apical sealer tip placement, larger apical diameters or gauges, and pumping actions significantly increase the risk of extrusion, particularly with sealers that are delivered in a syringe, such as BioRoot Flow. These findings underscore the significance of procedural control in minimizing sealer extrusion and enhancing clinical outcomes.
Related Concept Videos
Modified-Release Drug Delivery Systems: Influencing Factors
Drug Delivery Systems: Different Types
Bioavailability: Influencing Factors
Factors Influencing Microbial Growth: pH
Factors Influencing Attraction I: Proximity
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...