Surgical Treatment for Benign Prostatic Hyperplasia: Holmium Laser Enucleation of the Prostate HoLEP.
Published on: March 6, 2018
Comparative Outcomes of MOSES™ 1.0 Versus 2.0 in Holmium Laser Enucleation of the Prostate Is There Really a
Rita R Palanjian1, Taylor Veschio2, Ava A Delu1
1Department of Urology, University of Arizona-Tucson, Tucson, Arizona, USA.
Introduction:
Holmium laser enucleation of the prostate (HoLEP) is a size-independent treatment for benign prostatic hyperplasia (BPH) that has emerged as the gold standard. Pulse-modulated energy delivery, MOSES™ laser technology, optimizes the delivery of energy by reducing energy loss between the laser fiber and tissue. This study aims to compare the operative parameters of HoLEP using MOSES™ 1.0 vs 2.0.
Materials And Methods:
We prospectively enlisted patients undergoing HoLEP at two sites in a single institution. Patients were assigned to MOSES™ 1.0 or 2.0 by site and remained blinded to laser settings. Primary outcomes were differences in postoperative hemoglobin and enucleation, morcellation and hemostasis times. Secondary outcomes were improvement in International Prostate Symptom Score, maximum urinary flow rate, proportion of prostate enucleated and enucleation efficiency.
Results:
Among 236 patients (median age 73 (46-90), 67 (28%) were assigned to the 1.0 group and 169 (72%) to the 2.0 group. Baseline demographics were similar, except higher rates of active anticoagulation in the 2.0 cohort (0 vs 8%, p < 0.03). The 2.0 group had significantly higher hemoglobin on postoperative day 1 (POD1) (1.0: 12.5 vs 2.0: 13.0, p < 0.05). Enucleation (51.0 vs 46.5 minutes) and morcellation (6.0 vs 7.0) were comparable. Hemostasis was 33% faster with the 2.0 (15.0 vs 10.0 minutes, p < 0.001), even when adjusted for prostate volume (p < 0.0001) and anticoagulation status (p = 0.001). Although not statistically different, the 1.0 cohort had higher rate of urinary tract infection (11.9% vs 6.0%), while the 2.0 cohort had more Clavien-Dindo IV complications (0% vs 1.2%) and clot retention (0% vs 1.2%).
Conclusions:
Compared with the 1.0, the MOSES™ 2.0 laser demonstrated significantly improved intraoperative hemostasis while maintaining comparable enucleation efficiency. Although POD1 hemoglobin values were higher with the 2.0 system, the difference was small and unlikely clinically meaningful. Secondary postoperative outcomes were also similar between groups. Our findings suggest that the primary advantage of the updated technology lies in enhanced hemostatic performance rather than procedural efficiency.
Related Concept Videos
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Identifying Statistically Significant Differences: The F-Test
Sum and Difference OpAmps
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...