Related Experiment Video
Updated: Feb 13, 2026

A Clinical Trial Assessing the Safety, Efficacy, and Delivery of Olive-Oil-Based Three-Chamber Bags for Parenteral Nutrition
Published on: September 20, 2019
Evaluating Safety Rules in Ongoing Dose-Escalation Trials Using BOIN: A Comparative Analysis of Criteria and Their
Stefan Englert1, Thomas J Prior2, Anirban Mitra3
1Statistical Modeling & Methodology, Janssen-Cilag GmbH, a Johnson & Johnson Company, Neuss, Germany.
Abstract:
Ongoing dose-escalation trials present unique challenges in assessing safety, all with the goal to establish the maximum tolerated dose (MTD) and/or the recommended phase II dose (RP2D). Due to the extended duration of trials, it is common to declare doses as safe even if the entire adaptive and iterative dose escalation process has not been completed. This practice is often applied to aid trial management decisions, such as starting region-specific dose-escalation studies, initiating combination therapies, or allowing intra-patient dose escalation in previous cohorts, to enhance efficiency and accelerate the pace of drug development. Whereas regulatory agencies often require a safety margin for the starting dose for regional or combination dose-escalation studies, there exists a misperception within the research community that once an escalation assessment team has cleared a cohort for escalation, the associated dose level is inherently safe. Given that dose escalation algorithms permit repeated de-escalations, previously cleared doses may not be truly safe, necessitating a quantification of this risk and identifying an adequate safety margin. Through rigorous simulation studies, we identified criteria that must be met to confidently declare dose levels as safe within the Bayesian optimal interval (BOIN) design. Our comparative analysis of safety criteria shows that evaluating a minimum of three subjects at the dose level above the one to be declared safe is essential for accurate safety assessments and protecting patients. More aggressive dose-escalation paradigms would risk exposing patients to doses that are not ultimately declared safe.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Survey Safety
Household Wiring And Electrical Safety
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Drug Dosing: Infants and Children