Determination of thallium by solution anode glow discharge atomic emission spectrometry with an interference filter
Jinmei Wang1, Tao Hu1, Peichao Zheng1
1Chongqing Municipal Level Key Laboratory of Photoelectronic Information Sensing and Transmitting Technology, School of Electronic Science and Engineering, Chongqing University of Posts and Telecommunications, Chongqing 400065, China. zhengpc@cqupt.edu.cn.
Abstract:
A novel, cost-effective solution anode glow discharge atomic emission spectrometry system with an interference filter (SAGD-IF-AES) is reported for the determination of trace thallium (Tl) in water. The system integrates a SAGD excitation source with a low-cost interference filter as a compact spectral discrimination device, addressing the limitations of conventional bulky and expensive spectrometers. Key operational parameters, including solution flow rate, pH, discharge gap, and current, were systematically optimized. Under the optimal conditions (3.6 mL min-1, pH = 2, 2 mm gap, and 60 mA current), the system achieved a low detection limit of 0.53 µg L-1 for Tl with excellent linearity (R2 > 0.999) and high precision (RSD of 1.1%). This performance, comparable in order of magnitude to that of spectrometer-based SAGD-AES, confirms the feasibility of the filter-based approach. However, significant signal suppression from common matrix ions (Na+, K+, Ca2+, and Mg2+) was observed, indicating a challenge for the direct analysis of complex samples. The method's accuracy was validated using a certified reference material, yielding satisfactory recoveries of 95-105%. This work provides a technical pathway toward developing portable analytical devices for on-site heavy metal monitoring.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Related Concept Videos
Atomic Emission Spectroscopy: Interference
Emission Spectra
Determining the pH of Salt Solutions
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview