Related Experiment Video
Updated: Feb 14, 2026

Remotely Supervised Transcranial Direct Current Stimulation: An Update on Safety and Tolerability
Published on: October 7, 2017
Postmarketing Safety of Transcranial Magnetic Stimulation: A 10-Year MAUDE Database Analysis of Adverse Events and
Ali Imam Awan1,2, Nida Waheed3, Rida Zahra4
1Maimonides Medical Center, Brooklyn, New York.
Abstract:
Background: Transcranial magnetic stimulation (TMS) is an FDA-cleared neuromodulation technique with expanding clinical applications beyond major depressive disorder. Despite increasing utilization, there has been no published, device-agnostic analysis of TMS-related adverse events (AEs) using the FDA's Manufacturer and User Facility Device Experience (MAUDE) database.
Abstract:
Objective: To characterize the real-world safety profile of TMS devices based on MAUDE-reported AEs, including symptom patterns, manufacturer-level variations, device issues, and reporting delays, while contextualizing findings through a review of technological advancements in TMS.
Abstract:
Methods: All reports under device code OBP were extracted from MAUDE through April 2025. After deduplication, 200 unique reports were analyzed descriptively. A focused literature review was also conducted to trace safety and innovation trends in TMS device development.
Abstract:
Results: Of 200 reports, 94.7% involved injury, 4.1% malfunction, and 1.2% death. Common symptoms included anxiety (8.2%), neurocognitive changes (8.0%), seizures (6.9%), headache (6.9%), and tinnitus (5.6%). Neuronetics accounted for 45.5% of reports, likely reflecting market share. Median reporting delay was 1.4 months, with some exceeding 6 years. The literature review identified major innovations, including figure-of-eight and H-coils, double-containment coils, seizure risk screening, and advanced circuitry (eg, insulated-gate bipolar transistors and metal-oxide-semiconductor field-effect transistors) enabling magnetic resonance imaging-guided and accelerated protocols. Exploratory developments include wearable systems, auricular stimulation, and artificial intelligence-based individualization.
Abstract:
Conclusion: MAUDE data provide novel insights into TMS safety in real-world settings. Although serious AEs are rare, standardized reporting and continued device innovation are essential to ensure safe and effective clinical use.
Related Concept Videos
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Survey Safety
Local Anesthetics: Adverse Effects
Once absorbed into the systemic circulation, local anesthetics can affect the organs that depend on the functioning of sodium...
Household Wiring And Electrical Safety
Integration of Synaptic Events
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...