Ultra-dense lutetium oxide ceramic scintillators for positron emission tomography
Akram Hamato1, Daehee Lee1, Ryosuke Ota1,2
1Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, United States of America.
None:
Objective.Lutetium oxide (Lu2O3), with its high density (9.4 g cm-3), presents a compelling scintillation host for detecting 511 keV annihilation photons in positron emission tomography (PET). Despite its favorable density, the practical deployment of Lu2O3-based scintillators for PET has faced limitations due to difficulties in crystal growth and inappropriate decay time. Recent progress in ceramic processing has facilitated the development of transparent Lu2O3ceramics, while targeted doping strategies have significantly improved their luminescence performance. This study evaluates the performance of Lu2O3:Yb and a newly developed ceramic scintillator of (Lu,Y)2O3:La, a modified Lu2O3-based compound incorporating yttrium (Y) and doped with lanthanum (La).Approach.Various ceramic disks were fabricated and cut into 3 × 3 × 5 mm3samples. The performance of both Lu2O3:Yb and (Lu,Y)2O3:La ceramic samples in terms of decay time, energy resolution, and coincidence timing resolution (CTR) was assessed. Decay time measurements were conducted using waveform data collected from samples mounted on an H10580 photomultiplier tube (PMT) and irradiated with 511 keV photons from a22Na source. Energy and CTRs were evaluated using both PMT and silicon photomultiplier setups, arranged in coincidence with a reference lutetium-yttrium oxyorthosilicate (LYSO) detector of the same size.Main results.All three (Lu,Y)2O3:La ceramic scintillator samples exhibited a triple exponential decay profile and were dominated by a slow component ranging from 1379.3 to 1515.6 ns. The best energy resolution of 15.4% at 511 keV and the best CTR of 237.9 ps full width at half maximum (FWHM) were observed for the same sample. In contrast, a fast decay time of 1.6 ns was observed for the Lu2O3:Yb samples, which exhibited CTR values ranging from 237.9 ps to 261.4 ps FWHM, while the photopeak at 511 keV was difficult to distinguish. These CTR values were estimated between two identical ceramic samples, derived from coincidence measurements of each ceramic sample against the LYSO reference detector. The (Lu,Y)2O3:La samples achieved CTR values comparable to those of the Lu2O3:Yb samples, as their much higher light yield offsets the disadvantage associated with their slower decay time.Significance.These results highlight the promising potential of the (Lu,Y)2O3:La ceramic scintillators for PET applications, especially for time-of-flight PET.
More Related Videos
10:20Automation of a Positron-emission Tomography PET Radiotracer Synthesis Protocol for Clinical Production
Published on: October 26, 2018
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Emission Spectra
Dense Connective Tissue
Dense Regular Connective Tissue
In dense regular connective tissue, fibers are arranged parallel to each other, enhancing its tensile strength and resistance to stretching in the direction of the fiber orientations. Ligaments and tendons are made of dense regular...
Oxidation Numbers
Pyruvate Oxidation
First, the enzyme pyruvate dehydrogenase removes the carboxyl group from pyruvate and releases it as carbon dioxide. The stripped molecule is then oxidized and releases electrons, which are then picked up by NAD+...