Proprioceptive limit detectors contribute to sensorimotor control of the Drosophila leg

Brandon G Pratt1,2, Chris J Dallmann1, Grant M Chou1

  • 1Department of Neurobiology and Biophysics, University of Washington, Seattle, WA, USA.

Nature Communications
|February 12, 2026
PubMed

Related Concept Videos

Muscles that Move the Leg01:23

Muscles that Move the Leg

The movement of the legs is facilitated by numerous muscles located within the anterior, medial, and posterior compartments of the thigh.
Anterior Compartment
The quadriceps femoris, the most visible muscle of the anterior compartment, is integral for leg extension and thigh flexion. It is formed by merging four distinct muscles — the vastus lateralis, vastus medialis, vastus intermedius, and rectus femoris. The quadriceps tendon, a shared tendon of the four quadriceps muscles, is affixed...
5.4K
Limiting Reactant02:27

Limiting Reactant

The relative amounts of reactants and products represented in a balanced chemical equation are often referred to as stoichiometric amounts. However, in reality, the reactants are not always present in the stoichiometric amounts indicated by the balanced equation.
70.6K
Binet's Contribution to Measures of Intelligence01:23

Binet's Contribution to Measures of Intelligence

Alfred Binet, along with his student Théophile Simon, was tasked by the French Ministry of Education in 1904 to create a method for identifying students who struggled to learn through conventional classroom instruction. This initiative aimed to address overcrowding by placing such students in specialized schools. Binet and Simon developed an intelligence test comprising 30 tasks, ranging from simple commands, like touching one's nose or ear, to more complex tasks, such as drawing...
1.8K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
1.7K
The Number e as a Limit01:29

The Number e as a Limit

The number e is a fundamental constant in calculus, playing a central role in describing continuous change, particularly exponential growth. It is most naturally defined through its relationship with the natural logarithm, which is the inverse of the exponential function with base e. This relationship allows e to be characterized using basic principles of differentiation rather than as an arbitrary numerical constant.A key property of the natural logarithm function, ln x, is that its derivative...
102
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
2.1K