Related Experiment Video
Updated: Feb 14, 2026

Modified Experimental Conditions for Noise-Induced Hearing Loss in Mice and Assessment of Hearing Function and Outer Hair Cell Damage
Published on: February 10, 2023
Optimizing the Chinese Zodiac-in-Noise Test With Antiphasic Stimuli for Better Hearing Loss Detection
Yanqing He1, Nengheng Zheng2, Huali Zhou3,4
1School of Physics and Optoelectronics, South China University of Technology, Guangzhou, China.
Objectives:
The antiphasic digit-in-noise test has demonstrated the advantages of antiphasic presentation in hearing screening. Inspired by this, this study explores whether incorporating antiphasic stimuli in the Chinese zodiac-in-noise (ZIN) test can enhance its sensitivity to detect hearing loss. Furthermore, this study investigates the relation between the binaural intelligibility level difference (BILD), calculated as the difference between antiphasic and diotic results, and hearing thresholds, and evaluates the potential of BILD as an indicator for hearing loss.
Design:
Normative data for the antiphasic ZIN test were established based on data from 117 normal-hearing listeners. Subsequently, the performance of the antiphasic ZIN test was evaluated in 195 listeners with varying degrees and types of hearing loss. Participants were classified into four groups based on their audiograms: normal hearing (n = 115), symmetric hearing loss (n = 37), asymmetric hearing loss (n = 14), and unilateral hearing loss (n = 29). BILD was further analyzed to assess its relation with high- and low-frequency hearing thresholds.
Results:
The antiphasic ZIN test has a cutoff value of -13.7 dB and a reference speech reception threshold of -19.0 ± 3.2 dB. The measurement error, as estimated from the test-retest reliability, was 1.2 dB. Partial correlation analysis controlling for age revealed comparable associations of hearing thresholds across ears with BILD ( ρpoorer-antiphasic = 0.65, 95% confidence interval [CI]: 0.54 to 0.74 versus ρpoorer-diotic = 0.43, 95% CI: 0.29 to 0.55). Compared with the diotic ZIN test, the antiphasic ZIN demonstrates higher sensitivity (0.88, 95% CI: 0.78 to 0.93 versus 0.49, 95% CI: 0.38 to 0.60) in detecting hearing loss of >25 dB HL in the poorer ear, with comparable specificity (0.86, 95% CI: 0.79 to 0.91 versus 0.97, 95% CI: 0.93 to 0.99). Compared with high-frequency hearing loss, BILD showed a stronger association with low-frequency hearing loss, with a more pronounced decrease as hearing impairment in the poorer ear worsened.
Conclusions:
The antiphasic ZIN test demonstrates higher screening sensitivity compared with the diotic ZIN, particularly in detecting asymmetric and unilateral hearing loss. BILD is more sensitive to low-frequency hearing impairments and shows substantial promise as an indicator for hearing loss.
Related Concept Videos
Hearing
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Minor Losses in Pipes
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...