Related Experiment Video
Updated: Feb 14, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Assessment of the Mechanical Performance of AlCrSiN Coating Implanted with Zr and Ta Ions
Jing Liang1, Laia Ortiz-Membrado1,2, Raul Bonet3
1CIEFMA-Department of Materials Science and Engineering, EEBE, Universitat Politècnica de Catalunya-BarcelonaTECH, Avda. Eduard Maristany 16, 08019 Barcelona, Spain.
Abstract:
This study explores the impact of Zr and Ta ion implantation on the mechanical performance of an AlCrSiN quaternary coating deposited on a WC-Co cermet substrate. Nanoindentation tests revealed a decrease in hardness and elastic modulus after ion implantation, compared to unimplanted coatings. Moreover, microscratch and contact damage tests demonstrated improved adhesion and reduced surface damage for ion-implanted samples, with Ta implantation exhibiting the best performance. Scanning Electron Microscopy (SEM) and focused ion beam (FIB) cross-sectional analysis confirmed less severe damage in ion-implanted samples compared to unimplanted ones. These findings suggest that Zr/Ta ion implantation enhances the structural integrity and adhesion of AlCrSiN coatings under loading conditions commonly encountered in practical applications, despite a moderate reduction in intrinsic hardness and elastic modulus.
Related Concept Videos
Mechanically-gated Ion Channels
Ligand-Gated Ion Channel Receptor: Gating Mechanism
Common Ion Effect
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
Formation of Complex Ions