Related Experiment Video
Updated: Feb 14, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
A Reproducible Post-Valve-Replacement EHR Cohort for Comparative AI Studies
Malte Blattmann1, Mika Katalinic1, Adrian Lindenmeyer1
1Innovation Center Computer Assisted Surgery (ICCAS), Leipzig University, Semmelweisstrasse 14, 04103 Leipzig, Germany.
Abstract:
Background/Objectives: Valve replacement (VR) patients are at high risk of postoperative complications, but reproducible Electronic Health Record (EHR) benchmarks for evaluating sequential AI models in this setting are lacking. We develop a reproducible pipeline that extracts two EHR datasets from MIMIC-IV (a general-purpose and a predictive benchmark dataset) capturing perioperative histories, high-resolution time-series, and clinically motivated outcome labels. Methods: The cohort comprises 3890 VR patients with clinician-guided feature selection across diagnoses, procedures, laboratory measurements, medications, and physiological monitoring. As an exemplary use case, we define ICU readmission at first ICU discharge as a surrogate for postoperative risk and derive a predictive benchmark under strict label-leakage control. We then compare a Transformer model trained on tokenized longitudinal EHR sequences with Transformer and XGBoost baselines trained on aggregated feature statistics, and assess performance differences using paired statistical tests across validation splits. Results: ICU readmission stratified in-hospital and 100-day outcomes, including mortality, complications, and rehospitalization, confirming the clinical relevance of the prediction target. The sequential Transformer achieved 0.87 AUROC and 0.69 AUPRC. Corrected resampled t-tests confirm improved performance over the non-sequential Transformer, while the comparison with XGBoost indicates a favorable trend without conclusive evidence. Conclusions: Our findings suggest that leveraging longitudinal EHR sequences yields higher predictive performance than static feature summaries for postoperative risk prediction. The publicly released preprocessing pipeline and cohort-construction code enable researchers with MIMIC-IV access to reproduce the datasets and provide a robust benchmark for developing and comparing time-series models in post-valve replacement care.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Continuous Renal Replacement Therapy
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Mitral Valve Prolapse I: Introduction
Comparative Excretory Systems
Comparing Experimental Results: Student's t-Test

