Related Experiment Video
Updated: Feb 14, 2026

Rapid and Low-cost Prototyping of Medical Devices Using 3D Printed Molds for Liquid Injection Molding
Published on: June 27, 2014
Experimental Study on the Modified P-V-T Model to Improve Shrinkage Prediction for Injection-Molded Semi-Crystalline
Shia-Chung Chen1,2, Yan-Xiang Liang3, Chi-Je Ding3
1R&D Center for Smart Manufacturing, Chung Yuan Christian University, Taoyuan 32023, Taiwan.
Abstract:
Shrinkage of injection-molded parts is a major challenge for dimensional accuracy, especially for semi-crystalline polymers where crystallization induces pronounced volume change and heat release during cooling. Because packing pressure is effective only before gate or local solidification, multi-stage packing is commonly used to regulate the overall shrinkage behavior. In practice, however, the solidification/transition temperature taken from standard material tests does not necessarily represent the actual in-cavity state behavior under specific cooling rate and pressure history, which compromises the consistency of P-V-T-based shrinkage prediction. In this study, a modified P-V-T-based framework (Tait equation) is developed for polypropylene (PP) by introducing a Thermal Enthalpy Transformation Method (TETM) to determine a process-relevant solidification time and crystallization-completion temperature (including the corresponding target specific volume) directly from in-cavity melt temperature monitoring using an infrared temperature sensor. The novelty TETM utilizes the crystallization-induced enthalpy release to identify the temperature-time plateau, from which one can identify the effective solidification point. Because the Tait equation adopts a two-domain formulation (molten and solidified states), accurate identification of the domain-switching temperature is critical for reliable shrinkage prediction in practical molding conditions. In the experiment execution, the optimum filling time was defined using the minimum pressure required for melt-filling. Four target specific volumes, three melt temperatures, and two mold temperatures were examined, and a two-stage packing strategy was implemented to achieve comparable shrinkage performance under different target specific volumes. A conventional benchmark based on the solidification temperature reported in the Moldex3D material database was used for comparison only. The results show that the target specific volume determined by the TETM exhibits a more consistent and near-linear relationship with the measured shrinkage rate, demonstrating that the TETM improves the robustness of solidification-time identification and the practical usability of P-V-T information for shrinkage control.
Related Concept Videos
Polymer Classification: Crystallinity
Crystalline domains are the regions where polymer chains are aligned in an orderly manner and held together in proximity by intermolecular forces. For example, chains in the crystalline domains of polyethylene and nylon are bound together by van der Waals...
Polymers
Polymers
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction...