Related Experiment Video
Updated: Feb 14, 2026

Preparation of Carbon Nanosheets at Room Temperature
Published on: March 8, 2016
Sensitive Montmorillonite Evaporation Detector Based on Montmorillonite Monolayer Nanosheets
Jiahao Zhao1,2, Qinglin Jia2, Xu Wang2,3
1School of Materials Science and Engineering, North University of China, Taiyuan 030051, China.
None:
Two-dimensional (2D) materials open up exciting possibilities for the study of ion transport behavior for green energy. Here, a simple and effective strategy to fabricate high-conductivity nanofluidic channels based on exfoliated montmorillonite (MTM) nanosheets is proposed. The resource-rich and low-cost layered MTM was first exfoliated into monolayer nanosheets using Exolit OP 550. Subsequently, the MTM nanosheets with Exolit OP 550 were assembled into 2D nanofluidic devices by the layer-by-layer self-assembly method. The results show that Exolit OP 550 exfoliates different types of layered MTM into monolayer nanosheets with uniform contrast and integrity. The reconstructed Na-MTM nanofluidic device has the highest ionic conductance. The ionic conductivity of the Na-MTM 2D nanofluidic device was effectively improved after Li+ modification with a higher charge density. After further optimizing the content of Exolit OP 550, the ion conductivity of the MTM nanofluidic device reached 4.66 × 10-4 S cm-1, which is 55.3% higher than the highest known value among the same nanofluidic devices. Interestingly, this nanofluidic device exhibited a very high sensitivity in detecting water evaporation, which can reach 10-12 S s-1 in resolution. This economically viable strategy may advance the study of low-dimensional ion transport properties in new energy coatings and the design of evaporation detectors.
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...

