Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

105.2K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
105.2K
Improving Translational Accuracy02:07

Improving Translational Accuracy

15.0K
Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
15.0K
Improving Translational Accuracy02:07

Improving Translational Accuracy

3.7K
3.7K
Glassware Calibration01:11

Glassware Calibration

1.5K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.5K
Instrument Calibration01:12

Instrument Calibration

799
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
799
Accuracy and Precision01:52

Accuracy and Precision

15.7K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.  Highly accurate...
15.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Development of Marker-Based Motion Capture Using RGB Cameras: A Neural Network Approach for Spherical Marker Detection.

Sensors (Basel, Switzerland)·2025
Same author

The Location of the Center of Pressure on the Starting Block Is Related to Sprint Start Performance.

Frontiers in sports and active living·2020
Same author

Improvement in sprint start performance by modulating an initial loading location on the starting blocks.

Journal of sports sciences·2020
Same author

Calculation of the centre of pressure on the athletic starting block.

Sports biomechanics·2019
Same author

Comparación de la efectividad de ranibizumab intravítreo para el tratamiento del edema macular diabético en ojos vitrectomizados y no vitrectomizados.

Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde·2017
Same author

Comparison of the Effectiveness of Intravitreal Ranibizumab for Diabetic Macular Edema in Vitrectomized and Nonvitrectomized Eyes.

Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde·2016

Related Experiment Video

Updated: Feb 14, 2026

Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems
10:38

Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems

Published on: March 3, 2010

14.3K

Wand-Based Calibration Accuracy for Unsynchronized Multicamera Systems Without Timestamps.

Yuji Ohshima1

  • 1Faculty of Human Health, Kurume University, 1635 Miichou, Kurume 839-0851, Fukuoka, Japan.

Sensors (Basel, Switzerland)
|February 13, 2026
PubMed
Summary

This study introduces a new camera calibration method for asynchronous multicamera systems (Async MCS) used in marker-based motion capture. The method accurately calibrates cameras without relying on timestamps, improving 3D reconstruction accuracy.

Keywords:
camera parameterhuman motion measurementmotion capture

More Related Videos

Comparison of Predictive Performance of Three Lymph Node Staging Systems in Colorectal Signet Ring Cell Carcinoma Based on Machine Learning Model
07:13

Comparison of Predictive Performance of Three Lymph Node Staging Systems in Colorectal Signet Ring Cell Carcinoma Based on Machine Learning Model

Published on: April 18, 2025

765
Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision
07:57

Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision

Published on: April 29, 2014

14.0K

Related Experiment Videos

Last Updated: Feb 14, 2026

Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems
10:38

Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems

Published on: March 3, 2010

14.3K
Comparison of Predictive Performance of Three Lymph Node Staging Systems in Colorectal Signet Ring Cell Carcinoma Based on Machine Learning Model
07:13

Comparison of Predictive Performance of Three Lymph Node Staging Systems in Colorectal Signet Ring Cell Carcinoma Based on Machine Learning Model

Published on: April 18, 2025

765
Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision
07:57

Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision

Published on: April 29, 2014

14.0K

Area of Science:

  • Computer Vision
  • Motion Capture Technology
  • Robotics

Background:

  • Marker-based motion capture (MoCap) is crucial for various applications.
  • Asynchronous multicamera systems (Async MCS) offer flexibility but pose calibration challenges.
  • Existing calibration methods for Async MCS often depend on accurate camera timestamps, which are not always available.

Purpose of the Study:

  • To develop a robust wand calibration method for Async MCS that does not require accurate timestamp functions.
  • To improve the accuracy of camera parameter estimation in marker-based MoCap systems operating asynchronously.
  • To reduce 3D reconstruction errors in marker-based motion capture using Async MCS.

Main Methods:

  • Proposed a novel wand calibration technique for Async MCS.
  • Treated time offset in image acquisition as an optimization variable.
  • Enabled camera parameter estimation without relying on timestamp information.

Main Results:

  • Achieved significantly smaller 3D reconstruction errors (1.445 ± 0.833 and 1.746 ± 0.908 mm) compared to methods ignoring time offsets.
  • Demonstrated the effectiveness of the proposed method in environments with inaccurate camera timestamps.
  • Validated improved accuracy in camera calibration for marker-based MoCap.

Conclusions:

  • The proposed method provides a more accurate and practical solution for camera calibration in asynchronous multicamera systems.
  • This advancement enhances the applicability of marker-based MoCap in real-world scenarios where precise timestamping is unavailable.
  • The findings contribute to more reliable and precise motion capture data acquisition.