Related Experiment Video
Updated: Feb 14, 2026

Using Laser Scanning Microscopy to Determine Electromigration in Molybdenum Disilicide
Published on: May 23, 2025
Rapid Determination of Molybdenum (VI) in Water Using Phenylfluorone-Modified Test Strips Combined with Colorimetry
Xingping Li1, Daiwei Zhuang2,3, Xiaoling Liu4
1School of Ecological Engineering, Henan Forestry Vocational College, Luoyang 471002, China.
None:
Excessive molybdenum (VI) (Mo (VI)) in water threatens environmental safety and human health, yet rapid on-site methods for Mo (VI) determination remain limited. Here, we propose a rapid method for Mo (VI) determination using phenylfluorone (PF)-modified test strips with dual readouts: visual colorimetry and image-based analysis in the CIELAB (Lab*) color space, and demonstrate its applicability using urban park water samples. Based on visual colorimetry, a standard color card was established, providing a screening range of 0.08 to 0.8 mg L-1 (A blank (0 mg L-1) was used as the baseline reference). Moreover, by the LAB color space, the linear relationship between the color development results of the PF-modified test strip and the A channel conforms to y = 21.08 + 8.82x (R2 = 0.992), with a detection range of 0-0.8 mg L-1. The total detection time was reduced to 2.5 min. To evaluate accuracy in real matrices, influent, midstream, and effluent samples from Chengdu Living Water Park were analyzed, with UV-vis spectrophotometry used as the reference method. The test-strip results agreed well with UV-vis spectrophotometry, with relative errors below 5%. Overall, this study provides a portable, rapid, and accurate method for the detection of Mo (VI) in water, and has potential application prospects in the field of water environment detection in the future.
More Related Videos
Related Concept Videos
Water and Mineral Acquisition
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Color Vision
Space Trusses
At the core of a space truss lies the fundamental unit known as the tetrahedron. This structure is composed of six members that form a three-dimensional shape...
State Space Representation
Consider an RLC circuit, a...