The Measurement of Unsteady Surface Pressure Using a Remote Microphone Probe
Published on: December 3, 2016
Center of Pressure Measurement Sensing System for Dynamic Biomechanical Signal Acquisition and Its Self-Calibration
Ni Li1, Jianrui Zhang1, Keer Zhang1
1College of Intelligent Manufacturing, Long Dong University, Qingyang 745000, China.
Abstract:
The development of highly dynamic bipedal robots demands sensing capable of capturing key contact-related signals in real time, particularly the Center of Pressure (CoP). CoP is fundamental for locomotion control and state estimation and is also of interest in biomedical applications such as gait analysis and lower-limb assistive devices. To enable reliable CoP acquisition under dynamic walking, this paper presents a foot-mounted measurement system and an online self-calibration method that adapts sensor scale and bias parameters during locomotion using both external foot sensors and the robot's proprioceptive measurements. We demonstrate an online self-calibration pipeline that updates foot-sensor scale and bias parameters during a walking experiment on a NAO-V5 platform using a sliding window optimization. The reported results indicate improved within-trial consistency relative to an offline-calibrated reference baseline under the tested walking conditions. In addition, the framework reconstructs a digitized estimate of the vertical ground reaction force (vGRF) from load-cell readings; due to ADC quantization and the discrete offline calibration dataset, the vGRF signal may exhibit stepwise behavior and should be interpreted as a reconstructed (digitized) quantity rather than laboratory-grade continuous force metrology. Overall, the proposed sensing-and-calibration pipeline offers a practical solution for dynamic CoP acquisition with low-cost hardware.
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Blood Pressure
Static, Stagnation, Dynamic and Total Pressure
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...